X
GEM-X255 Programming Instructions
L
NAPCO Security Systems
Page 48
WI1092E 10/05
AREA ARMING OPTIONS (ADDRESS 2650-2657)
PRIORITY AREA ARMING:
1. Select the desired arming area.
2. Enter the corresponding Area number in each the address location, in Binary (Bit) Format.
NOTE:
See Direct Address
Programming Example on page 15.
3. Press
U
or
D
to save.
NOTE:
Dark shaded data value box shows option not available.
REMOTE ACCESS LOGGING (ADDRESS 3184)
REMOTE ACCESS LOGGING
:
Enable logging of every keypad access event.
1. Select the desired option entering the option number (1-8) for each digit.
2. Enter corresponding option number in address location.
3. Press
U
or
D
to save.
AR
E
A
A
R
M
IN
G
O
P
T
IO
N
S
&
REMOTE A
C
CESS
L
O
GGING
ARMING
AREA
PRIORITY AREA ARMING
ADDR
A1
A2
A3
A4
A5
A6
A7
A8
1
2
3
4
5
6
7
8
1
2650
2
2651
3
2652
4
2653
5
2654
6
2655
7
2656
8
2657
[Default = blank (•) blank (•) from address 2650-2657]
3184 System Options - Enable Keypad
Default
Option
OFF
1
Enable Keypad 1
OFF
2
Enable Keypad 2
OFF
3
Enable Keypad 3
OFF
4
Enable Keypad 4
OFF
5
Enable Keypad 5
OFF
6
Enable Keypad 6
OFF
7
Enable Keypad 7
OFF
8
Enable Keypad 8