NAPCO Magnum Alert-800 Operating Manual Download Page 8

SHUNT button, labeled 

 and

enter your code. The yellow
SHUNT light and the 

red 

ARMED/

MEMORY light will come on. The

green light will be out. All zones

programmed by your alarm spe-

cialist to respond to manual
shunting will be shunted (even if
some are not in “trouble”).

Leave quickly when the red

ARMED/MEMORY light goes on.

Be sure to have all zones in

“trouble” repaired as soon as

possible.

when 

 return

When you enter through the

exit/entry door, the entry delay

Mini-Sounder will come on.

Check the red ARMED/

MEMORY light. If it is flashing,
an alarm occurred while you were
gone. Disarm the system with
your code from the keypad to
silence the sounder. NOTE: If

your system has a digital com-
municator, there may be a delay

while it is reporting an alarm

before your system disarms.

If the red ARMED/MEMORY

light was flashing before you
disarmed, it will go out briefly

then begin to flash a number of

pulses identifying the zone(s)
that had an alarm. Write down
the number of times the alarm

memory lamp flashes, so you will
have a record of which zone(s)
need attention. You may then
arm and disarm to cancel the
flashing alarm memory. If a zone

is still in alarm condition, you
will hear the Mini-Sounder for
three seconds. The red ARMED/

MEMORY light will go out. The

green STATUS light may start

flashing if zones are still in
“trouble” from the alarm.

If there was an alarm and the

red ARMED/MEMORY light did
not flash, the alarm was a 24 hour
zone (see your Alarm Plan). The

cause of the alarm will have to be

removed before you can clear

the alarm signal.

a

Technical Manuals Online! - http://www.tech-man.com

Summary of Contents for Magnum Alert-800

Page 1: ...OPERATING GUIDE FOR YOUR MAGNUM ALEm 800 800s SECURITY SYmM 01955 NAPCO Technical Manuals Online http www tech man com...

Page 2: ...is guide thor oughly to familiarize yourself with your new security system Keep this booklet handy for future reference Note especially the ALARM PLAN on page 15 Your alarm specialist will help you fi...

Page 3: ...in your premises Lets you exit and enter your premises without setting off an alarm after the system is armed Mb Buzzer at each Digit Key keypad warns that entry delay time is In progress It also sou...

Page 4: ...Four flashes trouble in Zone 4 shunt Ught Y8lknw l Steady one or more zones are shunted bypassed from the system MlnCSoundar l When you enter your premises the tone reminds you to reset the Control Ce...

Page 5: ...lerting a central station For example your afarm spe cialist may have set aside a zone each zone temporarily shunt re optional Your alarm specialist move individual zones from the has programmed your...

Page 6: ...number you will remember such as your birthday 12 s 47 rather Chmg lyMlrm than something obvious like your Slide the switch into the LOAD address The nUmberSYOU choose position Enter a new c e into b...

Page 7: ...area protected by the zone s in trouble In this example you can fix the zones yourself by closing the back door and the window If the zone cannot be fixed immediately the green light will continue to...

Page 8: ...icator there may be a delay while it is reporting an alarm before your system disarms If the red ARMED MEMORY light was flashing before you disarmed it will go out briefly then begin to flash a number...

Page 9: ...d If an alarm signals at a time when your system is not armed an alarm is occurring on a 24 hour protection zone or your standby battery is low The cause of the alarm must be corrected and then the Co...

Page 10: ...git Key keypad Makesure you press both buttons at the s8me time The panic zone is capable of sending asilent signal to the Central Station when a Digital Communicator is being used optional The Penic...

Page 11: ...have programmed your security system to be monitored by a Central Station The built in digital communicator can trans mit emergency signals to the Centml Station 24 hours a day Technical Manuals Onli...

Page 12: ...ou to reset the system before a knowledge the fact that you have mits the Central Station to receive zone condition report is sent to armed your system by ringing a signal each time the system the Cen...

Page 13: ...the Fire Zone Press the spring loaded SILENCE 8 FIRE RESETswitch toshutoff the Mini Sounder The red TROUBLE light will come on until the Fire Zone is cleared When the zone is restored the Mini Sounder...

Page 14: ...cape procedures with those who use the building 1 If the premises is a residence sleep with the bedroom door closed A closed door will hold back deadly smoke while you escape 2 When the fire alarm sig...

Page 15: ...Zone Area Protected Zone Features Contacts doors windows etc 1 3 I 4 I Aux 6 Central Station Service Person optlonal katun Telephone Telephone 15 Technical Manuals Online http www tech man com...

Page 16: ...NAPCOLlMiTEDWARRANly Technical Manuals Online http www tech man com...

Reviews: