NAPCO Gemini C-Series Control Panel Installation Instructions--Volume 2
Page 56 Installation Instructions, Volume 2
RF Jam Reporting
RF Receiver Jam will report as RF Receiver Trouble.
Rotary Dialing Only
See
TouchTone Dialing Only
Schedule Assignment (Event Scheduler)
Access Schedules
For a particular User Code or Area, this screen allows the addition of pre-programmed events to take effect at a pre-
programmed Time / Date and/or time period. The Event selections are:
User On
- Enables the User Code
User Off
- Disables the User Code
Test Timer
(required in UL installations) - sends periodic test signal to the central station
Autodump History
-
Area Arm
- Auto arms the panel at a scheduled time
Area Disarm
- Auto disarms the panel at a scheduled time
Service Message
- a service reminder can be added
Test if Armed
- Used for Fail to Arm reporting; if the panel is not armed at a specified time, the panel will send a sig-
nal to the central station
Test if Disarmed
- Used for Fail to Open reporting; if the panel is not disarmed at a specified time, the panel will
send a signal to the central station
Trouble Resound
-
Open/Close Suppression Window
Used to suppress opening and closing reports to the central station during specified start and end times.
Holiday Dates
Used to suppress events during a specified holiday date / Time.
Second Call
If using the PCD-Windows PC downloader Software, the Telco Answering Service can now be disabled. Call the panel, hang
up after one ring. The PCD-Windows will automatically call the panel back and the panel will answer in one ring. See Call-
back-Method Download for more information.
Select Burg Bell on Keyfob Arming
This feature is associated with programming feature
Burg PGM1 Chirp on Keyfob Arm/Disarm
. Normally the chirp on a
keyfob arm/disarm is transmitted to the Burg Module PGM1 Output. Selecting "
Select Burg Bell on Keyfob Arming
" causes
the "Burg Bell" to chirp instead of the "Burg Module PGM1 Output" upon remote arming.
Selective Bypass
Disable Code Required for EZ Bypass
(Not for UL installations.)
Any or all zones (1–255) programmed for Selective Bypass may be removed from the system, but each must be removed
separately. Refer to BYPASSING ZONES in Section 3 for operation. Security Bypass: Recommended for commercial appli-
cations, requires entry of a valid user code. EZ Bypass: Recommended for residential applications, is selected by program-
ming Disable Code Entry for EZ Bypass; this will permit bypassing/unbypassing zones without the need of entering a code
(see EZ Bypass in Section 3). Do not program this feature in high-security applications. When one or more zones is by-
passed, the "
BYPASSED
" reminder on the GEMC-BK1 keypad will display.
Sensor Watch
Program for any zone containing a PIR or dual-technology sensor, floor mats, door contacts, or other device where some ac-
tivity is expected. This feature supervises the sensor by verifying that the zone activates before the PIR timer runs out. If no
trip is detected within the programmed Sensor-Watch time, a system trouble will result and "
E22-NN PIR SENSOR TRBL
" will be dis-
played at the keypad, where NN are the zone number(s). Select the RESET SENSOR MSG function to reset this system
trouble.
Program the Sensor-Watch Timer in the Quickloader
Time Selection
screen. Select a value in accordance with the antici-
pated activity within the coverage area while disarmed. In calculating the Sensor-Watch time, note that only the disarmed
hours (the time between armed periods) are added. In moderate traffic areas, a Sensor-Watch time of perhaps 1 hour may
be appropriate, whereas in remote areas, a time of 8 hours or more may be in order. Supervision time should be calculated
for the supervised zone with the least amount of traffic. Up to 255 hours may be programmed (see Time Selection).
Service Message: A
Report Telco 1
Report Telco
Service Message is programmed in the Event scheduler screen in PCD-Windows Quickloader. When schedule event
BURGLARY GLOSSARY