34
S Y S T E M T R O U B L E E R R O R C O D E S
Trouble
Indication
System Trouble
Condition
Action
E04-NN
Wireless Transmitter
Supervisory Failure
A problem has been detected with a wireless transmitter. Call installing company for service
E05-NN
Wireless Transmitter
Low Battery
The battery in a wireless transmitter is low and should be replaced. This transmitter is on the
zone corresponding to the number NN. The replacement battery for the GEM-TRANS2 door/
window transmitter, GEM-PIR motion detector and GEM-GB glass break detector is the Duracell
DL123A 3 volt lithium. (2 required for the GEM-PIR and GEM-GB.) The replacement battery for
the GEM-SMK is the Duracell MN1604 9 Volt Alkaline (2 required). The GEM-DT Dual
Technology Sensor requires 4 C cell alkaline batteries.
Warning: Replace batteries only with the same type as specified above. Use of another battery
may present a risk of fire or explosion. Do not recharge or disassemble battery, or dispose of in
fire.
E06-NN
Receiver Response
Failure
Call installing company for service.
E07-00
Download Failure
Call installing company for service.
E08-00
Telephone Line Cut
The telephone line has failed. If telephone service has been temporarily interrupted, the trouble
will clear automatically when it is restored. Otherwise, call installing company for service.
E09-00
System Cold Start
Summary of Contents for GEM-DK1CA
Page 39: ...39 NOTES...