Technical Manual PD4-E-M (EtherCAT)
7 Special functions
•
: Digital Outputs
•
: Target Velocity
7.3.4 Category: customer
•
h
: Customer Storage Area
7.3.5 Category: drive
•
h
: Motor Drive Submode Select
•
h
: Feedback Selection
7.3.6 Category: tuning
•
h
: Pole Pair Count
•
h
: Maximum Current
•
: I2t Parameters
•
h
: Encoder Configuration
•
: Feedback Incremental A/B/I 1
•
: SSI Encoder Multi Turn
•
h
: Motor Rated Current
•
6080
h
: Max Motor Speed
•
: Position Encoder Resolution
•
h
: Velocity Encoder Resolution
•
: Additional Position Encoder Resolution - Encoder Increments
•
h
: Additional Position Encoder Resolution - Motor Revolutions
7.3.7 Starting the save process
Note
•
The motor must be at a standstill during the save process and may not be started up while saving.
•
Saving may take a few seconds. Under no circumstances may you interrupt the voltage supply
while saving. The state of the saved objects is otherwise undefined.
•
Always wait until the controller has signaled that the save process has been successfully
completed with the value "1" in the corresponding subindex in object 1010
h
.
There is a subindex in object 1010
for each category. To save all objects of this category, the value
"65766173
h
" must be written in the subindex.
The controller signals the end of the save process by
overwriting the value with a "1".
The following table shows which subindex of object 1010
h
is responsible for which category.
Subindex Category
01
h
All categories with the exception of 06
h
(Tuning)
02
h
Communication
03
h
Application
04
h
User
05
h
Movement
06
h
Tuning
1
This corresponds to the decimal of
1702257011
d
or the ASCII string
save
.
Version: 1.0.1 / FIR-v1748