64
S 07
MAINTENANCE
Lubricate the gasket with glycerine. Install the O-ring/
gasket and cover..
CAUTION!
Do not use any petroleum-based products to lubricate the
inside of the pump. Only use glycerine. Other products
can damage the impeller, which will damage the pump
and lead to engine failure. Do not run the impeller without
water or lubricant, this can cause engine failure or a fire.
COOLANT FLUID REPLACEMENT
WARNING!
Do not remove the heat-exchanger pressurized cap when
the engine is hot. Then loosen the cap slightly to release
the excess pressure before removing it completely.
ENVIRONMENT!
Use a suitable container. Used oil must be disposed of as
specified in national and international laws and regula
-
tions.
Coolant drain
1. Stop the engine and allow it to cool.
2. To drain the coolant, remove the drain plugs (1) on
the engine block on the bottom of the injection pump.
3. Remove expansion bowl cap (2) and the plug (3) on
the exhaust gas manifold.
4. Unscrew clamps (4) and remove the hoses (5) and (6).
Summary of Contents for Q2400 Series
Page 1: ...NANNI GENERATOR SET USER MANUAL DGBXXT090041 Q2400 Series...
Page 2: ......
Page 4: ...4 Q00 TRACKED CHANGES...
Page 8: ...8 S00 SUMMARY...
Page 32: ...32 S03 FLUIDS...
Page 38: ...30 S05 COMPONENTS...
Page 40: ...32 S05 COMPONENTS VIEW N 1 OF THE GENERATOR SET...
Page 41: ...33 S05 COMPONENTS VIEW N 2 OF THE GENERATOR SET...
Page 53: ...53 S 07 MAINTENANCE...
Page 76: ...76 S 07 MAINTENANCE ELECTRIC DIAGRAM 50Hz SINGLE PHASE...
Page 77: ...77 S 07 MAINTENANCE ELECTRIC DIAGRAM 60Hz SINGLE PHASE...
Page 78: ...78 S 07 MAINTENANCE...
Page 80: ...80 S08 AL TERNATOR...
Page 100: ...100 S08 AL TERNATOR...
Page 108: ...108 S11 TROUBLE SHOOTING...
Page 109: ......
Page 110: ......