Page 37
5-1
Removing the Header Assy
The Header Assy can be removed to make it easier for the game to be moved
through doorways etc.
The Header assy has a forward centre of gravity, so it is important that at least two
(2) people are used to fit or remove the Header assy.
The fitting position of the Header assy is high, and it is important that a means of
reaching the height safely, without stretching, is available, (e.g. steps, step stool etc.).
1.
Remove the Header Acrylic. (see 7-3 page 62 Replacing the Fluorescent)
2.
Disconnect the Connector and remove 2off pozi head screws (M5x12)
3.
Remove 2off pozi head screws (M5x12) and remove the Header Assy.
4.
Refit the Header Assy in reverse order.
Pozi head screws (M5
×
12)
Connector
Header Assy
Pozi head screw (M5
×
12)
Monitor cabinet