P O R T A B L E A P P L I A N C E T E S T I N G
Please Note:
During testing of the machine with a portable appliance tester the insulation test will
show a failure due to the fitting of two VDRs between Live/Earth and Neutral/Earth.
These components have been fitted to safeguard against high voltage surges that may
occur on the mains supply to the machine and to comply with the EMC regulations.
To conduct an insulation test on this machine, the VDRs must be isolated from the
circuit first.
Ensure that the VDRs are reconnected after the insulation test has been completed and
before the machine is placed back into service.
The VDRs used have been specified and tested as safety critical components.
Summary of Contents for Race on!
Page 2: ......
Page 15: ...NAMCO EUROPE Ltd 500mm 230volt AC CPU 500mm 1990mm 3...
Page 31: ...Page 31 3 MAJOR COMPONENTS...
Page 39: ...Page 39 2 Games Linked 3 Games Linked 4 Games LinkedZ...
Page 41: ...Page 41 Linking Three Games Linking Four Games...
Page 76: ...Page 76 9 PARTS...
Page 86: ...Page 86 10 SCHEMATIC...
Page 87: ...Page 87...