ALNOR
®
systemy wentylacji
jest prawnie chronionym znakiem i technicznym patentem. Prawo do zmian zastrzeżone.
32
w
w
w
.al
nor
.c
om.
pl
Instrukcja obsługi
HRU-WALL-RC
14. Product fiche
Mark
ALNOR
Model
HRU-WALL-RC-150-60
SEC class
A
SEC warm climates
-18,1
kWh/m2.a
SEC average climates
-41,7
kWh/m2.a
SEC cold climates
-83
kWh/m2.a
Energy label
Yes
Unit typology
Residential - bidirectional
Type of drive
Multi-speed drive
Type of Heat Recovery System
Heat recovery
Thermal efficiency of heat recovery
74
%
Maximum flow rate
60
m
3
/h
Electric power input at maximum flow rate
6
W
Sound power level (L
WA
)
40
dBA
Reference flow rate
41
m
3
/h
Reference pressure difference
10
Pa
Specific power input (SPI)
0,08
W/m3/h
Control factor
0,65
Control typology
Local demand control
Maximum internal leakage rate
N/A
Maximum external leakage rate
1
%
Internal mixing rate
N/A
External mixing rate
N/A
Visual filter warning
N/A
Instructions to install regulated grilles
N/A
Internet address for preassembly/disassembly instructions
Airflow sensitivity to pressure variations
N/A
Indoor/outdoor air tightness
50
m
3
/h
AEC - Annual electricity consumption - warm climates
0,6
kWh
AEC - Annual electricity consumption - average climates
0,6
kWh
AEC - Annual electricity consumption - cold climates
0,6
kWh
AHS - Annual heating saved - warm climates
19,5
kWh
AHS - Annual heating saved - average climates
43,2
kWh
AHS - Annual heating saved - cold climates
84,4
kWh