6. Maintenance
Maintenance can be carried out by the user as indicated in page 28.
7. Disposal and recycling
Information on disposal of units at the end of life.
This product complies with EU Directive 2002/96/EC.
The symbol of the crossed-out dustbin indicates that this product must be collected
separately from other waste at the end of its life. The user must, therefore, dispose of
the product in question at suitable electronic and electro-technical waste disposal
collection centres, or else send the product back to the retailer when purchasing a new,
equivalent type device. Separate collection of decommissioned equipment for recycling,
treatment and environmentally compatible disposal helps to prevent negative effects
on the environment and on health and promotes the recycling of the materials that
make up the equipment. Improper disposal of the product by the user may result in
administrative sanctions as provided by law.
4.3 BACK UP button
In case the remote controller gets lost or the batteries are dead, the device can be controller, to a limited
extent, using the BACK UP button. You can choose speed 1 or 3 and turn off the heat recovery unit. (C image
pag.15). The airflow direction is always alternate and the operation mode (either comfort or efficiency) is the
last selected from the remote controller.
5. Synchronisation of a number of units
It is possible to synchronized up to 10 units contemporaneously, through wire (2 pole twisted pair type,
max 30m length) so to have mode and inversion time synchronized. When the unit is switched on for the
first time, the rotation direction of each unit (clockwise or anti-clockwise) is automatically established. Other
functionalities like speed, smart humidity control and boost, continue to be controlled independently on
each single unit.
Conditions and scenarios during synchronization process:
1. Each device must have been turned on independently. Turning on one device will NOT turn on the other
synchronized units.
2. The fan speed is set on each unit independently.
3. The change between Alternate / Extract / Intake modes
is independent for each unit. If, for example,
only in one unit the intake mode is turned on, the other units will continue to operate in alternate mode.
4. The change of the COMFORT / EFFICIENCY modes is synchronized, i.e. a change of mode in one unit results
in a change to all units.
Wiring diagram as per Fig. 16B
Speed
LED colour
Acoustic signal
speed 1
single green led
short, single
speed 3
double green led
short, single
OFF
red led
long