background image

EN

WWW.NAKAYAMATOOLS.COM

2

Safety instructions 

 

ATTENTION! 

 

During usage of electrical instruments the following main safety requirements should be observed which provide protection from electrical shock, protection 

from possible personal injuries and fire safety. 

 

Voltage in electric network should correspond to the rated voltage. In case it does not correspond one should use voltage regulator. Before starting using this 

device carefully read and follow the present instructions and regulations. 

 

Keep order at your working place. 

 

Mess at working place is the reason of accidents. 

 

Take into consideration influence of environmental factors. 

 

Do not allow water or other liquids penetration onto or inside the instrument as well as atmosphere precipitations. 

 

Do not work in premises with explosive or chemically active medium. Take care about proper lighting. 

 

Be aware of electrical shock. 

Avoid simultaneous contact with electric instrument and grounded objects such as pipes, heating elements. 

 

Do not allow children and bystanders to be present in working area.  Provide safety storage of your instruments. Instrument should be stored in dry premise 

with ambient air temperature over 0oc and away from reach of children. 

 

Keep cable undamaged. 

 

Do not carry the instrument holding by the cable, do not use the cable for unplugging from the socket. 

 

DO not allow the cable to contact with hot and Oily surfaces and sharp edges. 

 

Use extension cable. 

 

When the tool is used outdoors, use only extension cords intended for outdoor use and so marked. 

 

Fasten the part securely. Use fixing devices or clamps for firm fixing of the device. 

 

During work with the instrument keep stable position and do not try to reach objects which are out of reach. 

 

Maintain your instrument properly. 

 

Keep your instrument clean and in order. 

 

Follow the instructions for maintenance and parts change. 

 

Check regularly condition of plug and cable. In case of necessity of their change ask the specialist. 

 

Always unplug the instrument. 

 

After works completion, before servicing and when changing accessories such (such as saw blade) disconnect the instrument from the power supply. 

 

Do not leave adjustment keys in the instrument. 

 

After servicing or change of working parts always check that adjustment keys and wrenches are removed. 

 

Avoid unintentional starting Of the instrument. 

 

Do not carry instruments connected to power supply with your finger on the trigger. 

 

Before plugging in ensure the switch is in “OFF” position. 

 

Check the instrument for damages. 

 

All parts should be correctly assembled and satisfy to all conditions which guarantee proper operation of the instrument. 

 

Check for alignment Of moving parts, binding Of moving parts. 

 

Do not use the tool with damaged switch. Have defective switches replaced. 

 

Warning! 

 

The use Of any accessory or attachment Other than one recommended in this instruction manual or by the manufacturer may present a risk of personal 

injury. 

 

Repairs should only be carried out by qualified persons otherwise this may result in personal injury.

Proper use

 

Household electrical corn mill is designed for Corn grinding (wheat, rye, barley etc.) intended for domestic 

 

animals feeding. Device is allowed to use only for household purposes. It is not designed for industrial use. Do not use the device under exposure to atmos

-

pheric precipitation. Keep the device away from heat, direct sunlight and moist. 

Description of main parts

 

1. Corn mill body 

 

2. Engine 

 

3. Loading funnel for corn 

4. Regulating slider for corn supply 

 

5. Knife 

 

6. Sieve

Summary of Contents for FM1100

Page 1: ...en el WWW NAKAYAMATOOLS COM ART NO FM1100 016809 ...

Page 2: ...eep stable position and do not try to reach objects which are out of reach Maintain your instrument properly Keep your instrument clean and in order Follow the instructions for maintenance and parts change Check regularly condition of plug and cable In case of necessity of their change ask the specialist Always unplug the instrument After works completion before servicing and when changing accesso...

Page 3: ...regulated by the gate Switch the tool off only after processing all grain poured to the tray gate closing and complete grain processing in working chamber To change grinding coarseness change sieve in the working chamber DO not allow Overfilling of vessel for grinded grain loading This may lead to the damage of the tool Operating instructions Maintenance Regularly clean the tool from dust and gene...

Page 4: ... service life of the tool Fulfil all technical maintenance only after disconnecting the tool from the power supply After work completion wipe the tool from dust Make sure that ventilation holes are clean and free ATTENTION In case of own disassembling Of the tool within the guarantee period your guarantee for the too repair will become void Rules of operation and service life Before operation of t...

Page 5: ... διάρκεια της εργασίας με το μηχάνημα διατηρήστε σταθερή θέση και μην προσπαθείτε να φτάσετε αντικείμενα που βρίσκονται σε μη προσβάσιμα σημεία Συντηρείτε κατάλληλα το μηχάνημά σας Διατηρείτε το μηχάνημα καθαρό και σε καλή κατάσταση Ακολουθήστε τις οδηγίες που αφορούν στην συντήρηση και την αλλαγή εξαρτημάτων Ελέγχετε τακτικά την κατάσταση του βύσματος και του καλωδίου Σε περίπτωση που χρήζουν αντ...

Page 6: ...σιτηρά για άλεσμα κλείστε το καπάκι και ξεκινήστε την διαδικασία άλεσης στο θάλαμο εργασίας Για να αλλάξετε το μέγεθος της άλεσης αλλάξτε το κόσκινο που χρησιμοποιείτε Μην γεμίζετε πολύ τον σάκο συλλογής μπορεί να προκαλέσει ζημιά στο μηχάνημα Για να ξεκινήσετε την διαδικασία άλεσης ακολουθήστε τα παρακάτω βήματα Οδηγίες λειτουργίας Συντήρηση Το μηχάνημα θα πρέπει να καθαρίζεται σε τακτικά διαστήμ...

Page 7: ...μοκρασίες από 2 0C έως 40 0C Για να αποφύγετε την δυσλειτουργία του μηχανήματος αφού τοποθετήσετε το μηχάνημα στον χώρο εργασία από το κρύο θα πρέπει να το αφήσετε χωρίς να το λειτουργήσετε για τουλάχιστον 10 ώρες Μην βρέχετε το μηχάνημα και μην το αποθηκεύετε σε χώρο με πολύ υγρασία Πραγματοποιήστε τακτικά συντήρηση του μηχανήματος Η συντήρηση θα πρέπει να πραγματοποιείται αφού βγάλετε το μηχάνημ...

Page 8: ......

Reviews: