background image

16

8

. OPERATION

S

S

O

H

L

Release

Lock

H : Increased

O : Draining

S : Stop Draining

Drain Outlet Port

Drain Valve 

L : Decreased

Regulator Knob

Pressure Gauge

Filter Section

Bowl

Fig. 2

S

S

O

O

Adjusting Dome

Oil Filler Cap

Upper Oil Limit

Lower Oil Limit

Window

Oil Reservoir

O

Draining

S

Stop Draining

Hand Operating Knob

Oil Output Port 

Fig. 3

CAUTION

Make sure to turn the compressed air supply to the 
Air Line Kit is OFF, before replacing the Lubricating 
Oil or draining the water in Lubricating Oil.

Check the Lubricating Oil level everyday and before 
use. If Lubricating Oil level is low, Fill the oil bowl with 
Lubricating Oil up to the Upper Oil Limit on the bowl.

If collected water in the lubricator taints Lubricating 
Oil, replace the Lubricating Oil immediately.

8 - 1  Filter Regulator (Fig. 2)

(1) Regulator Section

Lock and Release of the Regulator Knob

Regulator Knob is equipped with Lock mechanism.

Release : Pull the Regulator Knob OUT to unlock.
Lock

: Push the Regulator Knob IN to the Lock position.

Adjusting Air Pressure

Turn the Regulator Knob while watching Pressure Gauge 
increase or decrease.

H direction : Air pressure is increased.
L direction : Air pressure is decreased.

(2) Filter Section

The water, dirt and debris are separated from the 
compressed air.
The separated debris is collected in the Bowl.

Draining

Opening and closing the Drain Valve.

O direction : Draining.
S direction : Stop draining.

To divert the drain to another location

Connect a hose with a 

ȭ

6mm I.D. (Not included / provided 

by the end-user.) to the Drain Output Port and divert to 
another location.

8 - 2  Lubricator (Fig. 3)

(1) Oil Amount (Fig. 3)

Check the Oil Amount in the Window.
If the Lubricating Oil level is low, add additional oil.

Supply Lubricating Oil to Upper Oil Level Limit of Fig. 3.

(2) Replacing the Lubricating Oil and draining the water in 

the Lubricating Oil (Fig. 3)
Opening and closing the Hand Operating Knob.

O direction : Draining.
S direction : Stop draining.

To divert the Lubricating Oil and drain the water to 

another location

Connect a hose with a 

ȭ

6mm I.D. (Not included / 

provided by the end-user.) to the Oil Outlet Port and divert 
to another location.

Summary of Contents for AL-H1206

Page 1: ...は圧縮エアーを使用してください エアー圧力は 1 次側 1 0MPa 以下 2 次側 0 85MPa 以下で 使用してください 圧縮エアーについて 化学薬品 有機溶剤を含有する合成油 塩分 腐食性ガス等を含む圧縮エアーは 使用しないでください ボウルの破損や作動不良の原因になります 配管用ホース 給気ホースの接続 ホースは 確実に接続してください 使用中にホースが外れるとホースがあばれ けがをするおそれがあ ります 配管用ホース耐圧 1 0MPa 以下 を守って使用してください 継手部について 継手部に衝撃を与えたり 負荷がかかる接続をしないでください 破損によりエアー漏れや 継手が折れ て配管用ホース 給気ホースがあばれるおそれがあります 落下について エアーラインキットを取り付ける場合は 平らな面に確実に取り付けてください エアーラインキットを 落下させた場合 故障やけがをするおそれが...

Page 2: ...psi Pressure exceeding 1 0MPa 145psi may cause the connection hose and supply air oil hose to rupture Inlet and Outlet Connections Do not hit impact or cause shock to the Inlet or Outlet Connector Connections Never put undo stress or load on the Inlet or Outlet Connector Connections Any damage to these components can cause air leakage and the inability of the inlet or outlet quick disconnect to ad...

Page 3: ...remove them as not to cause damage to them CAUTIONS for STORAGE INSTALLATION and OPERATION Do not use the Air Line Kit where corrosive gasses chemicals seawater water oils or steam exist Do not place in direct sunlight Do not use where the Air Line Kit is subject to vibration or repetitive shock Do not use where a heat source or radiated heat exist To conform to STORAGE INSTALLATION and OPERATION ...

Page 4: ...ny Name Business Hours U S Toll Free No Telephone No Fax No Web Address Industrial Div 8 30am to 17 00pm CST closed Saturday Sunday and Public Holidays 800 585 4675 847 843 7664 847 843 7622 www nskamericacorp com Contact Us Contact Us For U S Market Company Name Business Hours Telephone No e mail Address 8 00am to 17 00pm closed Saturday Sunday and Public Holidays 81 0 289 64 3520 webmaster ie ns...

Page 5: ...e Pressure Regulator Operating Range 0 05 0 85MPa 7 3 123 3psi Pressure Relief Automatic Relief Valve Applied lubricating oil ISO VG15 Liquid Paraf n or equivalent Oil Reservoir Capacity 85cm3 Dimensions W300mm x D120mm x H228mm Weight 2 2Kg Operation Environment Temperature 0 40 C Humidity MAX 75 No condensation Atmospheric pressure 800 1 060hPa Transportation and Storage Environment Temperature ...

Page 6: ...cator are damaged all components are replacable by the end user Refer to Table 2 and Table 3 Table 2 Name Model Manufacturer Filter Regulator W1000 8 W CKD Lubricator L3000 8 W C Table 3 Filter Regulator Replacing Option Name Model Manufacturer Filter Regulator Consumable Parts Kit This set includes the Diaphragm Assy Valve Assy Bottom spring Louver Element Baf e and Bowl O Ring W1000 KIT CKD Lubr...

Page 7: ...Regulator Knob IN to the Lock position Adjusting Air Pressure Turn the Regulator Knob while watching Pressure Gauge increase or decrease H direction Air pressure is increased L direction Air pressure is decreased 2 Filter Section The water dirt and debris are separated from the compressed air The separated debris is collected in the Bowl Draining Opening and closing the Drain Valve O direction Dra...

Page 8: ...e Kit install to the horizontal If Rear Mounting install the Air Line Kit to the horizontally on a vertical wall 9 1 Installation of the Air Line Kit 1 Horizontal Installation When the Air Line Kit is mounted from the bottom in a horizontal position Af x the Rubber Pads Standard Accessories 4pcs to the bottom of the Air Line Kit 2 Rear Mounting or Bottom Mounting Attach the Air Line Kit by the Mou...

Page 9: ...r Compressor IMPULSE Air Tool Fig 8 1 Connect the Connection Hose Standard Accessory to the Primary Joint of the Air Line Kit 2 Connect the Filter Joint of the air motor to the Secondary Joint ȭ6 One Touch Joint on the Air Line Kit 3 Place Exhaust Air Silencer Oil Hose into an empty container Exhaust outlet air and oil from the Siliencer 9 2 Connection of the Air Line Kit ...

Page 10: ...t Lubricating oil drip rate from 1 to 3 drops min Removing the air oil hose from the Secondary Joint ȭ6 One Touch Joint supply a small amount of oil directly into the air oil hose if bowl is completely empty Insuf cient number of oil drops Air Tool and Reducer internal components will be deprived of oil and the longevity will be dramatically shortened Set the Oil Drip Rate from 1 to 3 drops min Wa...

Page 11: ...2015 06 20 002 י ...