![background image](http://html.mh-extra.com/html/nakanishi/al-c1204/al-c1204_operation-manual_704457008.webp)
15
English
(1) Connect the
ȭ
6.0mm Air Hose to the Primary Joint.
(2) Connect the
ȭ
6mm air hose to the Secondary Joint to the Air Input Quick Disconnect on the front of the
CONTROLLER.
(3) Insert the
ȭ
6mm -
ȭ
4mm Conversion Adaptor into the Air Output Quick Disconnect on the front of the
CONTROLLER. Insert the
ȭ
4mm air hose from the
ȭ
6mm -
ȭ
4mm Conversion Adaptor to the 4mm Quick
Disconnect on the back of the motor (
ȭ
6mm -
ȭ
4mm Conversion adaptor : CONTROLLER's Standard
Accessories). (Fig. 6).
Fig. 6
Air Input Joint
Motor (EM-3030J / EM-3060J)
E3000 CONTROLLER
Air Output Joint
Primary Joint
Connector for Air Hose
Connection Hose
Secondary Joint
ȭ
6 One - Touch Joint
9 - 2 Connection of the Air Line Kit
Trouble
Inspection / Corrective Active
Broken connection hose and
supply air hose.
Replace the connection hose and supply air hose.
No air
À
ow.
Check the compressor power supply and the air compressor output.
Check if connection hose and supply air hose is broken, bent or
disconnected.
Check the Regulator and set to the correct air pressure.
Check all connection hose and supply air hose connections.
ON / OFF valve is OFF position. The ON / OFF valve set to ON position.
Air leakage.
Check all threaded joints and re-tighten if necessary.
Low air pressure.
Check the Compressor, Air Circuit, and Regulator.
Water, dirt and debris are collected
in the Air Filter.
Drain water, dirt and debris from the Air Filter bowl.
10
. TROUBLESHOOTING
If a problem or concern occur, please check the following items prior to consulting your dealer.
11
. DISPOSAL OF THE AIR LINE KIT
When disposal of an Air Line Kit is necessary, follow the instructions from your local government agency for proper
disposal of electrical components .