Nakanishi AL-A1205 Operation Manual Download Page 2

9

English

1

. CAUTIONS FOR HANDLING AND OPERATION

Read these warnings and cautions carefully and only use in the manner intended.

These warnings and cautions are intended to avoid potential hazards that could result in personal injury to the

operator or damage to the device. These are classi

¿

ed as follows in accordance with the seriousness of the risk.

Class

Degree of Risk

WARNING

A safety hazard could result in bodily injury or damage to the device if
the safety instructions are not properly followed.

CAUTION

A hazard that could result in light or moderate bodily injury or damage to
the device if the safety instructions are not followed.

WARNING

Handling
Connection to the Air Line Kit should be performed by a person with experience with
compressed air and air compressors.

Air Pressure
Compressed air is required. Do not exceed an air pressure of 1.0MPa at primary side and
0.85MPa at secondary side of the Air Line Kit.

Use of Clean Air
Do not use compressed air contaminated with chemicals, oil compounds, organic solvents,
salinity or corrosive gasses in order to avoid damage to the device.

Connection of connection hose and supply air hose
Connect the input connection hose and supply air hose securely to avoid accidental
disconnection during use. Input air pressure should never exceed 1.0MPa.
Pressure exceeding 1.0MPa may cause the connection hose and supply air hose to rupture.

Inlet and Outlet Connections
Do not hit, impact or cause shock to the Inlet or Outlet Connector Connections. Never put undo
stress or load on the Inlet or Outlet Connector Connections. Any damage to these components
can cause air leakage and the inability of the inlet or outlet quick disconnect to adequately
secure the connection hose and supply air hose.

Mounting the Air Line Kit
When installing the Air Line Kit, securely install the Air Line Kit by mounting it on a

À

at, level

surface. If the Air Line Kit is dropped, damage to the Air Line Kit and injury to the operator is
possible.

Oil Mist Filter Bowl

The bowl is made of a polycarbonate.
Do not use the Air Line Kit in conditions where chemicals or organic solvents are present in
the atmosphere.

Do not remove the bowl guard. Using the Air Line Kit without the bowl guard may cause

injury to the operator should the bowl burst.

When removing the bowl from the Oil Mist Filter, remove all pressure from the Input and
Output sides of the Air Line Kit.

Thank you for purchasing " AL - 1205 " Air Line Kit. This Air Line Kit will supply clean and dry cooling air to the Air
Bearing Spindle and Turbine Motor. THIS AIR LINE KIT IS NOT A SUBSTITUTE FOR AN AIR DRYER.
Read this and all the associated component Operation Manuals carefully before use. Always keep this Operation
Manual in a place here a user can referred to for reference at any time.

Summary of Contents for AL-A1205

Page 1: ...取 扱 説 明 書 OPERATION MANUAL 日本語 P1 P7 English P9 P15 AL A1205 エアーラインキット Air Line Kit OM K0654 ...

Page 2: ...r exceed 1 0MPa Pressure exceeding 1 0MPa may cause the connection hose and supply air hose to rupture Inlet and Outlet Connections Do not hit impact or cause shock to the Inlet or Outlet Connector Connections Never put undo stress or load on the Inlet or Outlet Connector Connections Any damage to these components can cause air leakage and the inability of the inlet or outlet quick disconnect to a...

Page 3: ...for cleaning carefully remove them as not to cause damage to them CAUTIONS for STORAGE INSTALLATION and OPERATION Do not use the Air Line Kit where corrosive gasses chemicals seawater water oils or steam exist Do not place in direct sunlight Do not use where the Air Line Kit is subject to vibration or repetitive shock Do not use where a heat source or radiated heat exist To conform to STORAGE INST...

Page 4: ...0 7MPa Air Pressure Drop 0 01MPa Drain Reservoir Capacity 25cm3 Safe Pressure Regulator Operating Range 0 05 0 85MPa Pressure Relief Automatic Relief Valve Dimensions W300 X D120 X H 266mm Weight 2 4kg Operation Environment Temperature 5 40 C Humidity MAX 85 Atmospheric Pressure 700 1 060hPa Transpotation and Storage Environment Temperature 10 60 C Humidity 10 80 Atmospheric Pressure 500 1 060hPa ...

Page 5: ... the Oil Mist Filter or Regulator are damaged all components are replacable by the end user Refer to Table 1 and Table 2 Table 1 Name Model Manufacturer Oil Mist Filter Assembly M2000 8 W S CKD Regulator R1000 8 W X1 Regulator R1000 8 W Table 2 Oil Mist Filter Replacing Optional Name Model Manufacturer Oil Mist Filter Consumable Parts Kit The set includes the O Ring Mantle and Bowl O Ring M2000 KI...

Page 6: ... and or debris to exceed the Upper Limit as shown in Fig 2 0 4 2 1 0 MPa 8 6 H Increased L Decrease Lock Release Regulator Knob L H Pressure Gauge Fig 3 Lock and Release of the Regulator Knob Regulator Knob is equipped with Lock mechanism Release Pull the Regulator Knob OUT to unlock Lock Push the Regulator Knob IN to the Lock position Adjusting Air Pressure Turn the Regulator Knob while watching ...

Page 7: ...Hose for Air Bearing Air Turbine 6 1 Installation of the Air Line Kit 6 2 Connection of the Air Line Kit 1 Horizontal Installation When the Air Line Kit is mounted from the bottom in a horizontal position Af x the Rubber Pads Standard Accessories 4pcs to the bottom of the Air Line Kit 2 Rear Mounting or Bottom Mounting Attach the Air Line Kit by the Mounting Screws Cross Recessed Truss Tapping Scr...

Page 8: ... supply air hose No air Àow Check the compressor power supply and the air compressor output Check if connection hose and supply air hose is broken bent or disconnected Check the Regulator and set to the correct air pressure Check all connection hose and supply air hose connections ON OFF Valve is OFF position The ON OFF valve set to ON position Air leakage Check all threaded joints and re tighten ...

Page 9: ...2013 04 20 002 י ...

Reviews: