FP0 A/D Converter Unit
3.2
Voltage Range
3-5
Matsushita Electric Works (Europe) AG
Corresponding table of A/D conversion values
Input voltage (mV)
A/D conversion value
–100.0
–2000
–75.0
–1500
–50.0
–1000
–25.0
–500
0.0
0
+25.0
+500
+50.0
+1000
+75.0
+1500
+100.0
+2000
Processing if the range is exceeded
Input value
Converted value
–100mV or less
–2000
+100mV or more
+2000
Summary of Contents for FP0-A80
Page 4: ...Table of Contents FP0 A D Converter Unit ii Matsushita Electric Works Europe AG...
Page 5: ...Chapter 1 Parts and Terminology...
Page 9: ...Chapter 2 Wiring and Input Range Setting Switch...
Page 13: ...Chapter 3 A D Conversion Characteristics...
Page 19: ...Chapter 4 I O Allocation and Program...
Page 27: ...Chapter 5 Specifications and Dimensions...
Page 32: ...FP0 A D Converter Unit Specifications and Dimensions 5 6 Matsushita Electric Works Europe AG...
Page 34: ...Index FP0 A D Converter Unit Matsushita Electric Works Europe AG I 2...