60cm (24in) above
30cm (12in)
on left
200cm (79in)
in front
30cm (12in)
from back wall
60cm (24in)
on right
Fig.
2
.1
DO NOT install unit in the following locations:
•
Near an obstacle that will block air inlets and outlets
•
Near a public street, crowded areas, or where noise from the unit will disturb others
•
Near animals or plants that will be harmed by hot air discharge
•
Near any source of combustible gas
•
In a location that is exposed to large amounts of dust
•
In a location exposed to a excessive amounts of salty air
Special considerations for extreme weather
If the unit is exposed to heavy wind:
Install unit so that air outlet fan is at a 90° angle to the direction of the wind. If needed, build a barrier
in front of the unit to protect it from extremely heavy winds.
See Fig.
2
.
2 and Fig.
6.
3 below.
2.
Outdoor unit installation
Split-type room air conditioner / Installation Manual
48 / 120 EN