NOTE:
When connecting multiple drainpipes, install the pipes as shown
<360
(14.2")
>100
(4 ")
4.Using a 65-mm (2.5")core drill, drill a hole in the wall. Make sure that the hole is
drilled at a slight downward angle, so that the outdoor end of the hole is lower
than the indoor end by about 12mm (0.5") This will ensure proper water drainage
(as shown). Place the protective wall cuff in the hole. This protects the edges of
the hole and will help seal it when you finish the installation process.
5. Pass the drain hose through the wall hole.Make sure the water drains to a safe
location where it will not cause water damage or a slipping hazard.
NOTE:
When drilling the wall hole,
make sure to avoid wires, plumbing,
and other sensitive components.
The drainpipe outlet should be at
least 50mm (1.9") above the ground.
If it touches the ground, the unit may
become blocked and malfunction.
Outdoor
Indoor
Wall
12(0.5")
Drill a hole
in the wall
L N
Below
360mm
Below
600mm
Below
100mm
Indoor Unit
Ceiling
Indoor Drainpipe Installation
Install the drainpipe as shown below.
1.Attach the mouth of the drain hose to the unit's outlet pipe.Sheath the mouth of
the hose and clip it firmly with a pipe clasp.
2.Cover the drainpipe with heat insulation to prevent condensation and leakage.
Support
1m~1.5m
Lean Downward over 1/100