文件编号
Doc.No.
NDT2920002
版次
Edition
第
5
版
Version5
实施日期
Implementation date
20181213
32
NDM3E-630
210
280
250
320
NDM3E-800
210
280
250
320
NDM3E-1250
210
/
250
/
NDM3E-1600
210
280
250
320
注:断路器排装或叠装时,检查联接母排或电缆保证空气绝缘距离不会减少
Note: Check the connected busbar or cable during rowing or stacking of
7.3 断路器叠装之间最小中心距离
7.3 Minimum center distance between stacked circuit breakers
规格
Specification
H(断路器上下距离)
H (distance of circuit breaker from bottom)
带 0 飞弧罩
With a 0 arcing
cover
不带 0 飞弧罩
Without a 0 arcing
cover
NDM3E-125
90
91
NDM3E-250
90
93
NDM3E-400
155
155
NDM3E-630
155
155
NDM3E-800/1250/1600
155
155
注:1、电缆绝缘联接
2、联接且无绝缘
3、产品通电前检查 0 飞弧罩或相间隔板装配到位。
Note:
1. Cable insulating connection
2. Connection without insulation
3. Check whether the 0 arcing cover or phase partition is assembled
properly before products are energized.
8、安装方式 Mounting Method
8.1 绝缘测试 Insulation test
本断路器出厂前已按标准规定绝缘测试。因断路器带有电子线路板,安装前如进行复测,必须按如
下步骤:
The breaker has gone through specified standard insulation test before factory delivery. Because
many PCBs are installed in the breaker, for re-testing, please conduct tests according to following
procedures:
(1)用 500VDC 兆欧表。
(2)在断路器处于断开状态,对进出连接板 1-2、3-4、5-6 之间,和 1、3、5 连接板(3 个连接板用