S4600-24X2CInstallation Instruction Manual
3 First power-on and start the switch
NADDOD Pte. Ltd.
25
Figure 3-8
Parameter settings of serial port (selection of serial port number)
4. Set the Baud rate as
115200
, the data bits as
8
, the odd-even check as
none
, the stop bits as
1
, the
traffic control as
XON/XOFF
, and click the button of
Connect
.
5. Use the serial port to connect to PC, you can see CLI shown in the following figure when you press
the Enter key on the PC.
Figure 3-9
Serial port display window
Please use the cables attached in the box, otherwise it may be incompatible.
3.4
Powering on the switch
After the switch is powered on and started, the terminal will show the self-inspection
information of the device, and after the self-inspection, the system will enter the command
line prompt (e.g., switch#), etc.