Presence Sensor does not
function
1. All units: No power to
sensor or defective sensor.
2. All units: Sensor not
connected to White wire
1. Check harness wiring as per applicable section
2. Connect the output of the sensor to the Red # 5 and
White # 4 connections on the terminal block.
Swing Side Presence
Sensor is activated by
opening or closing door
All units: Connection of sensor
to wiring harness was to
“Safety” not “Safety w/
Lockout”
Rewire Safety Sensor to “Safety w/Lockout” connector.
(pins Red # 5 and White # 4 connections on the terminal
block.)
Swing Side ACUGARD
2, swing side floor mat,
safety holding beams or
other accessories do not
function while door is
moving
All units: Connection of
accessories was made to
“Safety w/Lockout” not
“Continuous Safety”
Rewire accessory to “Continuous Safety” connection (Red
# 5 and Violet # 3 connections on the terminal block.)
Sensor shows activation
signal sent, but door does
not open
All units: Sensor not
connected properly to
activation connector
Check harness wiring as per applicable section
One sensor does not
activate both doors on a
simultaneous pair
All units: Sensor is not
connected to both control
boards
Install simultaneous pair harness (P/N 229953)
Swing Side Door sensor
does not function
1. All units: No power to
sensor or defective sensor.
2. All units: Sensor not
connected to Violet wire
1. Check harness wiring as per applicable section.
2. Connect the output of the sensor to the Red # 5 and
Violet # 3 connections on the terminal block
Troubleshooting continued
….