“Quick Set-Up” General Wiring and Settings for Acusensor 3
For greater details, see the Acusensor 3 Manual (P.N. 15-8911-3)
To adjust the pattern width
Areas 1 and 2 can be eliminated and/or areas 7 and 8.
(1 and 2 cannot be separated, neither can 7 and 8)
To adjust the width angle
Use the adjustment tool as shown below to change the width angle.
±7° can be achieved in 3.5° steps each click ( Right / Left )
See below for areas affected
Coverage Chart
Mounting
Height
79"
87"
94"
102"
110"
118"
A
6.3"
6.7"
7.5"
7.9"
8.7"
9.4"
B
16.5"
18.1"
20"
21.7"
23.2"
25.2"
C
31.5"
34.6"
37.8"
40.9"
44.1"
47.6"
D
49.6"
54.7"
59.8"
64.6"
69.7"
74.8"
E
87"
95.7"
104.3"
113"
121.7"
130.7"
F
62.6"
68.9"
75.2"
81.5"
87.8"
94.1"
G
40.9"
44.9"
48.8"
53.1"
57.1"
61.4"
Z
1.6"
1.6"
1.8"
2"
2.2"
2.4"