Omega Dimmer series User manual version 1.0 09.2011
15
limits from 50 to 100%.
"Patch"
- DMX channel setup for each output channel individually. Use buttons and encoder to
asigne each output a specific DMX address:
Example:
"Output 7"
"DMX in 401"
"Lamp Dynamic"
- a lamp on / off time settings. For lamp life increasing. Settings are set equal
for all output channels:
- for DMX Control from DMX input,
- for test mode,
- and from external analogue encoders.
"Lamp ON time "
"= 30 msec " -
default
"Lamp OFF time "
"= 0 msec " -
default
"Curve "
–
Lamp control curve selection. The first 5 options corresponding to different lamp
management curves, but the last ("Non-dim") - for Relay mode:
"Square "
"Linear " -
default
"Lin-Law"
"NACurve"
"S-Curve"
"Non-dim" -
for Relay mode
"Engineer menu"
- engineering settings. PIN2 required (****).
Engineering menu, default settings
"Total channels"
- Output channel count. Actual count of connected outputs. The limit from 1 to
48.
"NonDimm setting" -
Relay mode setup individually for each output channel using the graphical
editor.
"Period register"
-
Phase control period. Default = 580th
"Fan control"
-
Fan control. Are set the following parameters:
"Fan slow Temp" –
Minimum speed temperature,
"= 45 C "
- default
"Fan fast Temp"
– Maximum speed temperature,
"= 70 C "
-default
"Lamp off Temp"
– Regulators shut-off temperature,
"= 95 C "
-default
"Minimum speed"
- Minimum speed (20 - 100 %)
"= 33 % "
-default
"Fan off delay"
– Fan off time delay (0-30 min).