NA-DE 10551 Quick Start Manual Download Page 2

The maximum detection range can be realized when walking tangential to  the sensor (figure1) When
walking directly to the sensor detection range will be low. Because you will not be able to cut vertical
areas. Detection range of 10551 and 10651 is  9 meters as diameter, 4,5 meters as radius.

GUARANTY

We will remedy defects caused by material flaws or manufacturing faults. The warranty will be met
by repair or replacement at our own discretion. The warranty shall not cover damage to wear parts,
damage or defects caused by improper treatment or maintenance. Further consequential damage to
other object is excluded.
Claims under the warranty will only be accepted if the unit is sent fully assembled and well packed
complete with a brief description of the fault, a receipt or invoice ( date of purchase and dealer’s
stamp) to the appropriate Service Center.

USAGE AREAS

• At the building entrances, stair vestibules.
• At the long halls within the flats.
• At the places required within the flats.
• At the parking garage.
• At the requisite locations within the hotels.
• At the schools, hospitals and oil filing station.

“OFFERS EXTRA ENERGY SAVING FEATURE’’

GENERAL SECURITY CAUTIONS

• Take off the original package and control if there is any damage of transportation and general view
of the product.
• Do not use the product at cross purposes.
• Keep it away from water and moist areas.
• Do not use the product at dusty, dirty and rusty places.
• Do not supply high voltage.
• Do not apply any liquid.
• Protect from any stroke.
• Using 230-240V~ voltage is so dangerous that only the specialist electricians must install and apply.

CAUTIONS FOR INSTALLATION AND USAGE

• Installing must be carried out professionally in accordance with applicable national wiring and
electrical operating conditions.
• Turn of the network before mounting.
• Do not mount the product near the radiator and moist areas.
• Use 2A fuse the supply input.
• Factory setting; daylight adjustment is at darkness, time adjustment is at the shortest.
• Setting can be made 10 - 15 second after the releasing of the power.
• Time and daylight setting can be made during the day or night.
• Do not change the time and daylight settings abruptly.
• Do not make a second adjustment before you get a result from the first setting of the time and
daylight.
• After you determine the right setting of the daylight, you can arrange the time as you need.
• The best result for the daylight setting can be obtained by adjusting the minimum. And that you
can find the correct setting for sensitivity incrementally.
• When a cleaning needed for the glass, take of carefully and clean with a dry rag.
• Avoid mounting the detector close to objects that can cause rapid temperature changes such as
heaters, fans, refrigerators and ovents etc, and prevent the detector from point-blank sunshine.
• It can cause the device operate inaccurately if there is tree, brushes etc. in the coverage area.
• The product has Y type connection.
• The product functions can be affected by the wind in the open area conditions.

(e) Daylight setting

The sensor’s response threshold can be infinitely varied from 2-2000 lux.
If you turn the knob clockwise device will operate at dark.

     Control dial set    = daylight operation approx. 2000 lux.
     Control dial set    = night-time operation approx. 2 lux.

(f) Time setting

Light ON time can be adjusted continuously from “5 sec. 

±

 1 sec. / 5 min. 

±

 10 sec.” If you turn

the knob anticlockwise device will operate at minimum time. (10 seconds)

Control dial set to  - = Shortest time (5 sec. 

±

 1 sec.)

Control dial set to + =  Longest time (5 min. 

±

 10 sec.)

NOTE:

 Device will automatically make its own offset by checking environment for approximately

5 minutes after the first installation. After this period device will operate normally. If you think
the device does not operate normal in first installation, please wait for 5 minutes and start to
test again. Be sure that there is no motion by this period.

DETECTING RANGE

TROUBLESHOOTING

MALFUNCTION

CAUSE

SOLUTION

• Led’s are off.

• There is no
electricity on the
device

• Continuously
leds is on

• Change perception
area in device

• Daylight adjustment set to
night-time mode during daytime
operate
• Power switch off or no electricity

• Fuse faulty

• Fuse switch off or fuse faulty

• Connection faulty.

• Continuously movement in
detection zone
• Cars on the streets are being
detected.
• Wind, rain, snow is moving to the
trees & bushes or open windows in
detection zone.

• Sudden temperature changes due
to weather(wind, rain, snow) or the
air expelled from fans.
• Different ambient temperatures.

• Control daylight setting and
re-adjust

• Check the electricity and power
on.
• Change the fuse.

• Check the fuse if necessary use
a new fuse.
• Check the connection cables.

• Check the detection zone.

• Avert it is being detection.

• Change detection zone, change
site of installation.

• Change site of installation or keep
the reasons away.

• Change site of installation.

DETECTION AREA :

Detection area of motion sensors depends on the angle between PIR detector and moving direction,
temperature , mounting style and mounting place. Temperature is very important for operation for
motion sensor like all electronic devices. Environment temperature will cause   to decrease of detection
range. Detection range given is determined at +20°C. If the weather is hot, it will decrease.

GB

10551 - 10651

CEILING ARMATURE WITH 360° MOTION

SENSOR AND EMERGENCY LIGHTING

Detection range is +20°C ambient temprature determined at.

Walking targential to the sensor

4.5 m

Walking directly to the sensor

2.5 m

Figure 1

As shown in figure, firstly open the string by turning
counter clockwise and take off the glass. Mount the
ceiling from places which shown in figure (c) and figure
(d). And first will connect ground connection, than
connect connector as shown in system components
part. Then lay the glass its place and fasten up the
glass by constricting the string.

(a) Clamping washer   (b) Glass Cover    (c) Ceiling mount   (d) Ceiling mount screw
(e) Daylight setting nobe   (f) Time setting nobe

Batteries are

out of warranty

KK-10551/10651_150414_ENG_00

www.na-de.com.tr   •   [email protected]

‹stanbul Deri Organize Sanayi Bölgesi Tufle Sok. No:8

M1-8 Özel Parsel 34953 Tuzla / ‹STANBUL - TÜRK‹YE

SETTING

SYSTEM COMPONENTS

(10651)

(c)

(e)

(f)

(d)

L

N

Neutral

Phase

Earth

N

L

(10551)

Neutral

Phase

Earth

(c)

(e)

(f)

(d)

L

N

(a)

(b)

2.8 m.

9 m.

4.5 m.

4.5 m.

360°

Complies with ROHS Regulation Directive 2002/95/EC

3

TS EN 60669-2-1
TS EN 60598-2-1

SPECIFICATIONS

10651

Operating voltage
Angle of coverage
Mounting Height
Detection Range
Time setting
Protection class
Opr. temperature
The amount of light emitted
Emergency lighting
Emergency lighting duration
Battery
Power consumption (Active/Stand-by)

10551

-
-
-

8.5W / 1W

40 lm

2 hours

3x1.2V 1000mAh ni-mh AAA

9W / 1.8W

230-240V~   50/60 Hz

360°

2.8 m.

9 m.

5 sec. 

±

 1 sec. / 5 min. 

±

 10 sec.

IP20      Class I
-20°C ~ +40°C

WW (3000K): 529 lm / CW (6500K): 575 lm

Summary of Contents for 10551

Page 1: ...lim uygulamay n z S v tatbikinde bulunmay n z Darbelere kar koruyunuz Cihazda 230 240V gerilim bulundu u i in uzman olmayan ki ilerce dokunulmas ve montaj n n yap lmas tehlikeli ve sak ncal d r MONTAJ...

Page 2: ...e can be adjusted continuously from 5 sec 1 sec 5 min 10 sec If you turn the knob anticlockwise device will operate at minimum time 10 seconds Control dial set to Shortest time 5 sec 1 sec Control dia...

Page 3: ...in strijd met de instructies zijn niet door de waarborg gedekt Overigens verwerpt onze onderneming alle aansprakelijkheid voor alle verdere schade die hierdoor aan andere producten of materialen zou w...

Page 4: ...arbres etc qui se trouvent proximit peuvent causer de troubles de perception L appareil contient une connexion de type Y Si le c ble de cette armature d clairage est endommag le remplacement doit tre...

Page 5: ...h her als 20 C Leistung kann beeinflusst werden Den maximalen Erfassungsbereich kann man nur erreichen wenn eine Bewegung parallel zum Sensor erfolgt Wenn die Bewegung frontal zum zum Sensor verlauft...

Page 6: ...40V voltios Avisos Sobre El Usoy Montaje Debe hacers el montaje del aparato de conformidad con las normas nacionales de cablear y instalar Antes del montaje siempre apaguen el interruptor el ctrico In...

Page 7: ...i B lgesi 12 yol M1 8 Parsel 34953 Tuzla STANBUL T RK YE 3 TS EN 60669 2 1 TS EN 60598 2 1 SA KK 10551 10651_150414_SA_00 2 8 m 9 m 4 5 m 4 5 m 360 230 240V 50 60 Hz 360 2 8 m 9 m 5 sec 1 sec 5 min 10...

Reviews: