Supported Commands 

Notes: 

1)

 

When applicable, PMBus commands use the direct data format. 

2)

 

Packet Error Checking (PEC) is not supported. 

3)

 

General Call Address (0x00, Global Broadcast) is not supported.  

4)

 

All PMBus reads are a combined data format, where there is no stop condition (stop bit) between the 
write  data  portion  (PMBus  command)  and  the  read  data  portion.  Instead,  there  is  a  repeated  start 
condition (start bit) before the change of direction (repeated slave address with read bit) in the transfer. 

 
Refer to the PMBus Specification Part II for detailed descriptions of the following supported commands: 

OPERATION 0x01 

An OPERATION command will cause the OPERATION byte to be written if the data is valid, but the command 
will  only  be  processed  if  the  RE  (Remote  Enable)  signal  is  not  at  logic  low  at  the  time  that  the  OPERATION 
command is issued. Valid data values that can be written to the OPERATION byte are 0x00 and 0x80. All other 
values  will  be  discarded.  A  change  in  the  state  of  the  remote  enable  (RE)  signal  will  override  any  previous 
OPERATION command that was issued. 
 
Data of 0x80 will enable the main and 12Vaux outputs. 
Data of 0x00 will disable the main and 12Vaux outputs. 

CLEAR_FAULT 0x03 

Clears the status byte and status word. 

STATUS_BYTE 0x78 

Returns the Low byte of the Status Word. See Table 8. 

Summary of Contents for XL270 Series

Page 1: ...PMBus Interface User s Guide XL270 Series 270 Watt AC to DC Power Supplies 706679 Rev 09 26 18...

Page 2: ...us org media PMBus_Specification_Part_II_Rev_1_0_20050328 pdf The PMBus is a logical protocol based on the SMBus that was originally conceived by Intel Corporation They both utilize the 5 volt I2 C ha...

Page 3: ...part numbers for the mating housing and crimp style snap in terminals are listed in Table 2 There may be equivalent connector components available from other manufacturers J6 Molex P N Number of Circ...

Page 4: ...ring and service use CAN LOW LOW data line for CAN Controller area Network communications for current sharing and service use RS Remote sense for RTN RS Remote sense for VOUT compensates for load cabl...

Page 5: ...t Sharing J3 10 CAN Low CANL for Current Sharing J3 11 Negative Remote Sense RS J3 12 Positive Remote Sense RS J3 13 Power Fail Power Good PF PG J3 14 Remote Enable ENABLE J3 15 Not used Table 4 J3 Pi...

Page 6: ...esses These are determined by selectively grounding the two high true address input lines shown in Table 4 Leaving the address pins open will be treated as logic high J3 3 A1 J3 4 A0 Address Open Open...

Page 7: ...Part II for detailed descriptions of the following supported commands OPERATION 0x01 An OPERATION command will cause the OPERATION byte to be written if the data is valid but the command will only be...

Page 8: ...UT Not supported 4 MFR Not supported 3 POWER_GOOD The POWER_GOOD negation has occurred 2 FANS Not supported 1 OTHER Not supported 0 UNKNOWN Not supported Table 8 Status Byte Word Description READ_VOUT...

Page 9: ...data value of 930d The parameters used to translate the data to the actual temperature information are given below Parameter Value m 620d b 24800d R 2d Table 11 PMBus direct format coefficient paramet...

Page 10: ...modulating the fan power then the returned tachometer pulse count per second value is only valid when the fan is powered at 100 duty cycle continuous power A fan with an open collector tachometer outp...