N2Power XL270 Series User Manual Download Page 2

 

 

E

NGINEERING 

D

EPARTMENT

 

706679 Rev 09-26-18 

1 of  9 

 

User’s Guide 

XL270 PMBus Interface 

 
This document and the PMBus™ firmware described within are subject to change without notice. PMBus is a 
trademark of System Management Interface Forum, Inc. 

The N2Power XL270 Series of power supplies optionally supports the industry standard PMBus. This document 
lists the commands that are currently supported in Version 1.2 of the XL270 PMBus implementation. Refer to 
the complete XL270 Product Specification (Document 706601) for details about the power supply’s operational 
characteristics. 

Refer to the PMBus Power System Management Protocol Specification Parts I and II 

 

Part I: General Requirements, Transport and Electrical Interface 

 

Part II: Command Language 

The PMBus documents can be downloaded at the following URLs: 

 

http://pmbus.org/developers.php

 

 

http://pmbus.org/media/PMBus_Specification_Part_I_Rev_1_%200_20050324.pdf

 

 

http://pmbus.org/media/PMBus_Specification_Part_II_Rev_1_0_20050328.pdf

 

 

The PMBus is a logical protocol based on the SMBus that was originally conceived by Intel Corporation. They 
both  utilize  the  5-volt  I

2

C  hardware  bus.  The  3.3-volt  integrated circuits of XL270 can tolerate the 5-volt I

2

Bus.  Electrical  and  timing  requirements  must  comply  with  the  I

2

C  Bus  specifications.  These  physical 

requirements are generally fulfilled by an integrated circuit. External pullup resistors on the I

2

C clock and data 

lines are required. The XL270 I

2

C inputs provide weak pullups to 3.3V to keep the clock and data input signals 

in their high state when not used.

 

Option Connector (J3) 

The J3 connector is a Molex Pico-Blade header (a.k.a. a jack) with 1.25mm pin spacing. The Molex part 
numbers  for  the  mating  housing  and  crimp-style  snap-in  terminals  are  listed  in  Table  1.  There  may  be 
equivalent connector components available from other manufacturers. 

               J3 

Molex P/N 

Number of Circuits (pins) 

15 

Mating Housing (white) 

51021-1500 

Crimp Terminal 

50212-8100 

Rated Contact Current 

2 A 

Rated Wire Size 

AWG 30 thru 24 

Table 1   J3 Mating Connectors 

Summary of Contents for XL270 Series

Page 1: ...PMBus Interface User s Guide XL270 Series 270 Watt AC to DC Power Supplies 706679 Rev 09 26 18...

Page 2: ...us org media PMBus_Specification_Part_II_Rev_1_0_20050328 pdf The PMBus is a logical protocol based on the SMBus that was originally conceived by Intel Corporation They both utilize the 5 volt I2 C ha...

Page 3: ...part numbers for the mating housing and crimp style snap in terminals are listed in Table 2 There may be equivalent connector components available from other manufacturers J6 Molex P N Number of Circ...

Page 4: ...ring and service use CAN LOW LOW data line for CAN Controller area Network communications for current sharing and service use RS Remote sense for RTN RS Remote sense for VOUT compensates for load cabl...

Page 5: ...t Sharing J3 10 CAN Low CANL for Current Sharing J3 11 Negative Remote Sense RS J3 12 Positive Remote Sense RS J3 13 Power Fail Power Good PF PG J3 14 Remote Enable ENABLE J3 15 Not used Table 4 J3 Pi...

Page 6: ...esses These are determined by selectively grounding the two high true address input lines shown in Table 4 Leaving the address pins open will be treated as logic high J3 3 A1 J3 4 A0 Address Open Open...

Page 7: ...Part II for detailed descriptions of the following supported commands OPERATION 0x01 An OPERATION command will cause the OPERATION byte to be written if the data is valid but the command will only be...

Page 8: ...UT Not supported 4 MFR Not supported 3 POWER_GOOD The POWER_GOOD negation has occurred 2 FANS Not supported 1 OTHER Not supported 0 UNKNOWN Not supported Table 8 Status Byte Word Description READ_VOUT...

Page 9: ...data value of 930d The parameters used to translate the data to the actual temperature information are given below Parameter Value m 620d b 24800d R 2d Table 11 PMBus direct format coefficient paramet...

Page 10: ...modulating the fan power then the returned tachometer pulse count per second value is only valid when the fan is powered at 100 duty cycle continuous power A fan with an open collector tachometer outp...

Reviews: