background image

ESERV-M12T-1210

  

R2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

820 S. University Blvd., Suite 4 E, Mobile, AL  36609 USA 
251.342.2164 
www.n-tron.com 
Copyright, © N-Tron Corp., 2010 

 

 

 

 

S

S

e

e

t

t

u

u

p

p

 

 

N

N

e

e

t

t

w

w

o

o

r

r

k

k

 

 

 

I want DHCP

 is preselected to set up the network using 

dynamic IP addressing. The Modbus Gateway is set up at 
the factory to receive an IP assignment from a DHCP 
Server. If a DHCP Server is not available on your network, it 
will default to 

169.254.102.39

.  

 

If a DHCP server is not available and the default address 

does not work on your PC, change your PC network 
settings to IP Address: 169.254.102.1, Subnet Mask: 
255.255.0.0, Default Gateway: 169.254.102.100. If you are 
not able to use these settings in your installation, refer to 
the user’s manual for directions to change the Modbus 
Gateway’s TCP/IP settings.  

 

 

 

 

 

S

S

e

e

t

t

u

u

p

p

 

 

M

M

o

o

d

d

b

b

u

u

s

s

 

 

T

T

C

C

P

P

 

 

Modbus TCP Settings: 

 

Connect to Port

 identifies TCP port used in TCP client 

mode. Valid range is 1 to 65535. 

 

Response timeout

 is the maximum response time. Valid 

range is from 1 to 65535. 

TCP Server Settings:

 

 

Listen on port

 identifies TCP port in TCP server mode. 

Valid range is from 1 to 65535. 

 

Limit the number of connections

…Controls the number of 

simultaneous TCP clients that can be connected. 

 

“…allow everyone

,” “…

allow specific IP address

” & 

allow a range of IP addresses

” are 

Connection Filter 

Mode

 options, controlling which TCP clients can connect. 

 

 

 

 

 

 

 

 

 

S

S

e

e

t

t

u

u

p

p

 

 

P

P

o

o

r

r

t

t

 

 

1

1

 

 

S

S

e

e

r

r

i

i

a

a

l

l

 

 

 

Change the 

Description

 of the serial port if needed. 

 

Set the 

Mode

 to RS-232, RS 422 (4 wire), RS 485 (2 wire) 

or RS 485 (4 wire). 

 

Set the 

Baud Rate

 to control the speed of the port. Valid 

speeds range between 75 and 230,400 bits per second. 

 

Set 

Data Bits

 to control the number of bits in each 

character. Only 8 bits is valid when the protocol of the 
device connected to the port is RTU. 

 

Stop Bits

 controls the number of bits for end of character. 

 

Parity

 controls the error checking mode, with options of No 

Parity, Odd, Even, Mark and Space. 

 
 

 

 

 

 

S

S

e

e

t

t

u

u

p

p

 

 

P

P

o

o

r

r

t

t

 

 

1

1

 

 

M

M

o

o

d

d

b

b

u

u

s

s

 

 

 

Select the 

Attached

 as 

Master

 or 

Slave

 

Select the 

Modbus

 protocol to be used, either 

RTU

 or 

ASCII

 

As needed, check option boxes for “

Enable Modbus 

broadcast

, “

Enable OBh Exception

” and “

Enable 

serial message buffering.

” 

 

Select from 0 to 5 

Modbus Serial Retries

 

Enter 

Milliseconds Modbus Message Timeout

, from 1 

to 65535. 

 

Enter 

Milliseconds TX Delay

, from 1 to 65535. 

 

Set up “Port 2 Modbus” the same, only if it has a Port 2. 

 

 

 

 

 

 

 

 

 

 

S

S

e

e

t

t

u

u

p

p

 

 

P

P

o

o

r

r

t

t

 

 

1

1

 

 

I

I

D

D

 

 

R

R

e

e

m

m

a

a

p

p

 

 

 

Only use this screen if 

Modbus Slave ID

s are to be 

remapped. 

 

On each line select a range of serial ports to remap. In the 

1

st

 box enter the first serial port of the range to remap 

From

. Valid port IDs range from 1 to 255. 

 

2

nd

 box - enter the last serial port of the range to remap. 

 

3

rd

 box - enter starting ID of the range to remap 

To

 

The 4

th

 box auto fills based on ranges entered in the first 

three columns. 

 

Set up “Port 2 Remap” the same, only if it has a Port 2. 

 

 

 

 

 

 

 

 

 

S

S

e

e

t

t

u

u

p

p

 

 

M

M

o

o

d

d

b

b

u

u

s

s

 

 

I

I

D

D

 

 

R

R

o

o

u

u

t

t

i

i

n

n

g

g

 

 

 

Only use this screen if 

Modbus Slave ID

s are to be re-

routed. 

 

On each line select the range of 

ID

s to re-route. In the 1

st

 

box enter the starting ID. Valid IDs range from 1 to 255. 

 

2

nd

 box – enter the last 

ID

 of the range to re-route. 

 

3

rd

 box - enter the 

IP Address

 or 

Port

 that has slave 

devices attached. 

 

The 4

th

 box shows the IP address of the slave device, if 

an IP address is chosen in the third box.  

 

 

 

 

 

 

 

S

S

e

e

t

t

u

u

p

p

 

 

M

M

o

o

d

d

b

b

u

u

s

s

 

 

P

P

r

r

i

i

o

o

r

r

i

i

t

t

y

y

 

 

 

Only use this screen if 

Modbus Priority

 is to be set. 

 

Enter up to five different priorities, based on 

Originating IP 

Address

Modbus ID

Modbus Function Code

, or a 

combination of these. 

 

IP Address

 sets a static IP address for the Modbus 

gateway. 

 

Modbus ID

 has a valid range from 1 to 255. 

 

Function Code

 has a valid range from 1 to 99. 

 

 

 

 

 

S

S

a

a

v

v

e

e

 

 

a

a

n

n

d

d

 

 

L

L

o

o

g

g

o

o

u

u

t

t

 

 

 

If you have completed the configuration, click Save to save 

the configuration to the serial server. 

 

To Logout, click the Logout button. 

 

 

 

 

 

T

T

o

o

 

 

T

T

e

e

s

s

t

t

 

 

a

a

n

n

d

d

 

 

V

V

e

e

r

r

i

i

f

f

y

y

 

 

O

O

p

p

e

e

r

r

a

a

t

t

i

i

o

o

n

n

 

 

 

The primary check for correct operation is the device 

LEDs. See Section 3 this document for more information. 

 

For advanced information, see the 

Modbus Configuration 

Manager

 menu, at the top of Modbus Gateway Manager 

screen. 

 

Select 

Diagnostic

 for a check of communications status 

with attached ESERV-M12T device, and then select the 
device for which the communications check is desired. 

 

A report of reply times and ping statistics is generated and 

can be saved. 

 

Select 

Monitor

 to review activity logs of attached ESERV-

M12T devices, then select the device for which logged 
information is needed 

 

Logged information includes 

Time

Source & Destination

Type

 of event, Subscriber ID

Data

 collected, and 

Information

 the Modbus Gateway Manager program has 

gathered since current login of the affected device. 

 
 
 
 
 
 
 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
 
 
 
 
 
 
 
 
 
 

 

 

 
 

 

 

8

13

 

14

 

15

 

16

 

Reviews: