ESERV-1xT module
This Quick Start Guide
CD with Software Manager and manuals
Network cable (not included)
Serial cable(s) (not included)
10 to 58V DC (4W) Power Supply (not
included)
Quick Start Guide
ESERV-1xT Serial Servers
1
I
I
n
n
s
s
t
t
a
a
l
l
l
l
t
t
h
h
e
e
H
H
a
a
r
r
d
d
w
w
a
a
r
r
e
e
2
Connect a 10 to 58 VDC power supply
Connect the network cable from the serial server to a
network drop using a standard network cable. Use a
straight-through Ethernet Cable on copper ports.
Connect the serial device(s):
o
RS-232 with DB9: straight-through for DCE
device, null modem for DTE device
o
RS-232/422/485 with terminal blocks: see
Appendix D for pinouts
L
L
E
E
D
D
S
S
t
t
a
a
t
t
u
u
s
s
LED
STATUS
Ready
Blinks if system is operating correctly
Port 1
On indicates serial port open, blinks when data present on
serial port
Port 2
Same as Port 1
(Present on 2 port units only)
Link
On indicates Ethernet operating in 100BaseTX, blinks
when data present on Ethernet link
3
M
M
o
o
d
d
e
e
S
S
w
w
i
i
t
t
c
c
h
h
Hold in Mode switch for…
Result
0 to 2 seconds
Initiates a Hardware Reset
2 to 10 seconds
Enters Console Mode
More than 10 seconds
Resets to Factory Defaults
4
I
I
n
n
s
s
t
t
a
a
l
l
l
l
M
M
a
a
n
n
a
a
g
g
e
e
m
m
e
e
n
n
t
t
S
S
o
o
f
f
t
t
w
w
a
a
r
r
e
e
Insert the included CD and it should autostart
Follow the prompts to install the Ethernet Serial
Server Manager software.
Note: Be sure you have administrative rights & disable firewalls
in Windows XP and Vista.
5
S
S
e
e
t
t
u
u
p
p
M
M
a
a
n
n
a
a
g
g
e
e
m
m
e
e
n
n
t
t
S
S
o
o
f
f
t
t
w
w
a
a
r
r
e
e
Open Ethernet Serial Server Manager: click
Start
Programs
N-TRON
Ethernet Serial
Server Manager
The Discovery page opens
To configure via the network, select Network.
If you know the IP address, select
The device is
at this address
, and type in the address. If not,
select
I don’t know the IP address of the device
.
Click Connect.
O
O
R
R
…
…
S
S
e
e
t
t
u
u
p
p
t
t
h
h
e
e
W
W
e
e
b
b
I
I
n
n
t
t
e
e
r
r
f
f
a
a
c
c
e
e
Open a browser and type the IP address of the
serial server in the Address Bar.
When the serial server is found, the
Configuration window appears.
6
o
One Conductor Per Terminal
o
Use Copper Wire Only
o
Wire Size: 28 to 16 AWG
o
Tightening Torque: 5 KG -CM
o
Wire Temperature Rating: 105°C Minimum
(Sized for 60°C ampacity)
o
80°C Maximum Surrounding Air Ambient