![N-Tron 716M12 User Manual & Installation Manual Download Page 105](http://html1.mh-extra.com/html/n-tron/716m12/716m12_user-manual-and-installation-manual_3193121105.webp)
For Sales and Support, Contact Walker EMD • www.walkeremd.com • Toll-free: (800) 876-4444 • Tel: (203) 426-7700 • Fax: (203) 426-7800
(Revised 2012-10-5)
Page 105 of 169
CIP – Status
The Status tab under the CIP category will display the CIP status.
The following switch status and partner status information will be shown:
Identity Information:
Product Name:
Switch Model Number.
Vendor:
This is N-Tron's ODVA Ethernet/IP Vendor ID (1006).
Device Type:
The ODVA Device Type is Communications Adapter (= 0x0C hex).
Major Revision:
The Major Revision of the CIP implementation.
Minor Revision:
The Minor Revision of the CIP implementation.
Serial Number (hex):
CIP Serial number, unique across all N-Tron CIP devices. This is the
last 4 octets of the base switch MAC.
Connection Information:
Number of Multicast
Connections:
Current number of CIP Ethernet/IP class 1 (multicast) connections.
Number of Unicast
Connections:
Current number of CIP Ethernet/IP class 3 (unicast) connections.