![N-Tron 708M12 User Manual & Installation Manual Download Page 16](http://html1.mh-extra.com/html/n-tron/708m12/708m12_user-manual-and-installation-manual_3191386016.webp)
(Revised 2012-10-5)
Page 16 of 169
N-TRON 708M12 Grounding Techniques
Drain wire with lug connecting switch chassis to known grounding point.
N-TRON 716M12 Grounding Techniques
Drain wire with lug connecting switch chassis to known grounding point.
CONNECTING THE UNIT
For 10Base-T ports, plug a Category 3 (or greater) twisted pair cable into the M12 connector. For
100Base-T ports, plug a Category 5 (or greater) twisted pair cable into the M12 connector. Connect
the other end to the far end station. Verify that the LNK LED’s are ON once the connection has
been completed. To connect any other port to another Switch or Repeater, use a standard Cat5
straight through or crossover cable.
Warning:
Creating a port to port connection on the same switch (i.e. loop) is an illegal operation
and will create a broadcast storm which will crash the network!
Summary of Contents for 708M12
Page 13: ...Revised 2012 10 5 Page 13 of 169 716M12...
Page 36: ...Revised 2012 10 5 Page 36 of 169 DHCP Server Setup Profiles Continued...
Page 40: ...Revised 2012 10 5 Page 40 of 169 DHCP Server Setup IP Maps Continued...
Page 64: ...Revised 2012 10 5 Page 64 of 169...
Page 83: ...Revised 2012 10 5 Page 83 of 169 IGMP RFilter Continued Modifying rfilter port settings...
Page 90: ...Revised 2012 10 5 Page 90 of 169 N Ring Advanced Configuration Continued...
Page 112: ...Revised 2012 10 5 Page 112 of 169...
Page 116: ...Revised 2012 10 5 Page 116 of 169...
Page 154: ...Revised 2012 10 5 Page 154 of 169...