Administration – Fault
The Fault tab under the Administration category provides configurable selections indicating the way to
notify when a Power, N-Ring Manager, N-Link fault, or Port Usage Fault occurs. The notification may
consist of any combination of the options: Show Web, Show LED, and Contact. Power signal faults consist
of V
1
and V
2
. N-Ring Manager signal faults consist of: Broken, Partial Break (Low), Partial Break (High),
and Multiple Managers. N-Link Faults are reported by the N-Link Master and by the N-Link Slave. Port
Usage Fault, if enabled, triggers when actual usage is below the Usage Alarm Low setting, or above the
Usage Alarm High setting (see Port Configuration View and Port Utilization View).
Note: V
1
and V
2
Power Faults are disabled in factory defaults.