N-Tron 105FX-POE User Manual & Installation Manual Download Page 3

 

Rev. 041008 

 
Copyright, © N-TRON Corp., 2008 
820 S. University Blvd., Suite 4E 
Mobile, AL USA 36609 
 
All rights reserved. Reproduction, adaptation, or translation without prior written permission from N-TRON 
Corp. is prohibited, except as allowed under copyright laws. 
 
Ethernet is a registered trademark of Xerox Corporation.  All other product names, company names, logos 
or other designations mentioned herein are trademarks of their respective owners. 
 
The information contained in this document is subject to change without notice.  N-TRON Corp. makes no 
warranty  of  any  kind  with  regard  to  this  material,  including,  but  not  limited  to,  the  implied  warranties  of 
merchantability  or  fitness  for  a  particular  purpose.    In  no  event  shall  N-TRON  Corp.  be  liable  for  any 
incidental,  special,  indirect  or  consequential  damages  whatsoever  included  but  not  limited  to  lost  profits 
arising out of errors or omissions in this manual or the information contained herein. 

 

 
 
 
 
 
 
Contact Information : 
 

N-TRON Corp. 
820 South University Blvd. 
Suite 4E 
Mobile, AL  36609 
TEL: (251) 342-2164 
FAX: (251) 342-6353 
Website: 

www.n-tron.com

 

Email: 

[email protected]

 

 
 

 

 

Summary of Contents for 105FX-POE

Page 1: ...Rev 041008 1 105TX POE 105FX POE Unmanaged Industrial Ethernet POE Switches User Manual Installation Guide...

Page 2: ...Rev 041008 2 Industrial Power over Ethernet Installation Guide 105TX POE 105FX XX POE 105FXE XX YY POE Where XX ST or SC and YY 15 40 or 80...

Page 3: ...ontained in this document is subject to change without notice N TRON Corp makes no warranty of any kind with regard to this material including but not limited to the implied warranties of merchantabil...

Page 4: ...nit with the end plates removed as this could create a shock or fire hazard WARNING Do not operate the equipment in a manner not specified by this manual ENVIRONMENTAL SAFETY WARNINGS WARNING Disconne...

Page 5: ...NG Explosion Hazard Do not remove or replace the device unless power has been switched off or the area is known to be non hazardous 5 Use 60 75 C rated Copper wire 0 22Nm 2 inch lbs Tightening torque...

Page 6: ...ey Features Compact space saving package Full IEEE 802 3 100Base FX Compliance IEEE 802 3af Compliant 105TX POE Five 10 100Base TX RJ 45 ports 4 PSE ports and 1 uplink port 105FX POE Four 10 100Base T...

Page 7: ...re the packaging in a safe place File any damage claims with the carrier CLEANING Clean only with a damp cloth INSTALLATION Read the following warnings before beginning the installation WARNING Never...

Page 8: ...ove the unit from the 35mm industrial DIN rail place a flat head screwdriver into the release clip found at the bottom of the unit and apply downward force on the clip until it disengages from the bot...

Page 9: ...POE POE Status LED SPD Speed LED 105TX POE only LNK ACT Link Activity LED RJ45 Ports Auto sensing 10 100BaseT Connection LED MODE OF OPERATION Note Redundant power inputs will not balance the power l...

Page 10: ...power on the wires after the wires have been secured to the switch WARNING Inserting the input plug while the 48VDC is applied may cause arcing and damage the input connector permanently Note Either...

Page 11: ...is grounded properly before applying power to the grounded switch This may be verified by using a voltmeter to determine that there is no voltage difference between the power supply s negative output...

Page 12: ...Rev 041008 12 RJ45 CONNECTOR CRIMP SPECIFICATIONS Please reference the illustration below for your Cat5 cable specifications...

Page 13: ...Rev 041008 13 TYPICAL APPLICATIONS STAR TOPOLOGY...

Page 14: ...Rev 041008 14 RING TOPOLOGY...

Page 15: ...pleted To connect any other port to another Switch or Repeater use a standard Cat5 straight through or crossover cable Warning Creating a port to port connection on the same switch i e loop is an ille...

Page 16: ...e harmful interference in which case the user will be required to correct the interference at his own expense INDUSTRY CANADA This Class A digital apparatus meets all requirements of the Canadian Inte...

Page 17: ...suitable for use in Class I Div 2 Groups A B C D T4 EMI EN 61000 6 4 EN 55011 Class A FCC Title 47 Part 15 Subpart B Class A ICES 003 Class A EMS EN6 1000 6 2 IEC 61000 4 2 ESD IEC 1000 4 3 RS IEC 610...

Page 18: ...to 85 C Storage Temperature 40 C to 85 C Operating Humidity 10 to 90 Non Condensing Operating Altitude 0 to 10 000 ft Network Media 10BaseT Cat 3 Cable 100BaseT Cat 5 Cable 100BaseFX Multimode 50 62 5...

Page 19: ...IES EXCLUSIVE IF AN N TRON PRODUCT DOES NOT OPERATE AS WARRANTED ABOVE CUSTOMER S SOLE REMEDY FOR BREACH OF THAT WARRANTY SHALL BE REPAIR REPLACEMENT OR REFUND OF THE PURCHASE PRICE PAID AT N TRON S O...

Reviews: