N-Tron 105FX-POE User Manual & Installation Manual Download Page 16

 

Rev. 041008 

16 

FCC STATEMENT 

 
This product complies with Part 15 of the FCC-A Rules. 
Operation is subject to the following conditions: 
(1)

 

This device may not cause harmful interference 

(2)

 

This  device  must  accept  any  interference  received,  including  interference  that  may  cause  undesired 
operation. 

 
NOTE: This equipment has been tested and found to comply with the limits for a Class A digital device, 
pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against 
harmful interference in a residential installation. This equipment generates, uses, and can radiate radio 
frequency energy and, if not installed and used in accordance with the instructions, may cause harmful 
interference to radio communications. Operation of this device in a residential area is likely to cause 
harmful interference in which case the user will be required to correct the interference at his own expense. 
 
 
 
INDUSTRY CANADA 
 
This Class A digital apparatus meets all requirements of the Canadian Interference Causing Equipment 
Regulations. Operation is subject to the following two conditions; (1) this device digital apparatus meets all 
requirements of the Canadian Interference Causing Equipment Regulations. Operation is subject to the 
following two conditions; (1) this device may not cause harmful interference, and (2) this device must 
accept any interference received, including interference that may cause undesired operation. 

 

Cet appareillage numérique de la classe A répond à toutes les exigences de l'interférence canadienne causant 
des règlements d'équipement. L'opération est sujette aux deux conditions suivantes: (1) ce dispositif peut ne 
pas causer l'interférence nocive, et (2) ce dispositif doit accepter n'importe quelle interférence reçue, y 
compris l'interférence qui peut causer l'opération peu désirée. 

 

Summary of Contents for 105FX-POE

Page 1: ...Rev 041008 1 105TX POE 105FX POE Unmanaged Industrial Ethernet POE Switches User Manual Installation Guide...

Page 2: ...Rev 041008 2 Industrial Power over Ethernet Installation Guide 105TX POE 105FX XX POE 105FXE XX YY POE Where XX ST or SC and YY 15 40 or 80...

Page 3: ...ontained in this document is subject to change without notice N TRON Corp makes no warranty of any kind with regard to this material including but not limited to the implied warranties of merchantabil...

Page 4: ...nit with the end plates removed as this could create a shock or fire hazard WARNING Do not operate the equipment in a manner not specified by this manual ENVIRONMENTAL SAFETY WARNINGS WARNING Disconne...

Page 5: ...NG Explosion Hazard Do not remove or replace the device unless power has been switched off or the area is known to be non hazardous 5 Use 60 75 C rated Copper wire 0 22Nm 2 inch lbs Tightening torque...

Page 6: ...ey Features Compact space saving package Full IEEE 802 3 100Base FX Compliance IEEE 802 3af Compliant 105TX POE Five 10 100Base TX RJ 45 ports 4 PSE ports and 1 uplink port 105FX POE Four 10 100Base T...

Page 7: ...re the packaging in a safe place File any damage claims with the carrier CLEANING Clean only with a damp cloth INSTALLATION Read the following warnings before beginning the installation WARNING Never...

Page 8: ...ove the unit from the 35mm industrial DIN rail place a flat head screwdriver into the release clip found at the bottom of the unit and apply downward force on the clip until it disengages from the bot...

Page 9: ...POE POE Status LED SPD Speed LED 105TX POE only LNK ACT Link Activity LED RJ45 Ports Auto sensing 10 100BaseT Connection LED MODE OF OPERATION Note Redundant power inputs will not balance the power l...

Page 10: ...power on the wires after the wires have been secured to the switch WARNING Inserting the input plug while the 48VDC is applied may cause arcing and damage the input connector permanently Note Either...

Page 11: ...is grounded properly before applying power to the grounded switch This may be verified by using a voltmeter to determine that there is no voltage difference between the power supply s negative output...

Page 12: ...Rev 041008 12 RJ45 CONNECTOR CRIMP SPECIFICATIONS Please reference the illustration below for your Cat5 cable specifications...

Page 13: ...Rev 041008 13 TYPICAL APPLICATIONS STAR TOPOLOGY...

Page 14: ...Rev 041008 14 RING TOPOLOGY...

Page 15: ...pleted To connect any other port to another Switch or Repeater use a standard Cat5 straight through or crossover cable Warning Creating a port to port connection on the same switch i e loop is an ille...

Page 16: ...e harmful interference in which case the user will be required to correct the interference at his own expense INDUSTRY CANADA This Class A digital apparatus meets all requirements of the Canadian Inte...

Page 17: ...suitable for use in Class I Div 2 Groups A B C D T4 EMI EN 61000 6 4 EN 55011 Class A FCC Title 47 Part 15 Subpart B Class A ICES 003 Class A EMS EN6 1000 6 2 IEC 61000 4 2 ESD IEC 1000 4 3 RS IEC 610...

Page 18: ...to 85 C Storage Temperature 40 C to 85 C Operating Humidity 10 to 90 Non Condensing Operating Altitude 0 to 10 000 ft Network Media 10BaseT Cat 3 Cable 100BaseT Cat 5 Cable 100BaseFX Multimode 50 62 5...

Page 19: ...IES EXCLUSIVE IF AN N TRON PRODUCT DOES NOT OPERATE AS WARRANTED ABOVE CUSTOMER S SOLE REMEDY FOR BREACH OF THAT WARRANTY SHALL BE REPAIR REPLACEMENT OR REFUND OF THE PURCHASE PRICE PAID AT N TRON S O...