From here, the Administrator’s Name, User ID and Password can be changed.  Also, Local users may be 
added by filling out a new row and selecting the add button.  Once Local users have been added, a user can 
be removed by selecting the delete button and can be updated by changing the information and selecting the 
update button. 
 

Callback Security Options: 
 

1)  Administrator: 
 

If the Callback Security option is enabled and 

Admin specified 

is selected, then enter your fixed 

callback telephone number in the 

Callback # 

window. If the 

Callback Security 

option is enabled and 

User 

Specified 

is selected, you do not enter a telephone number in the 

Callback # 

window. You enter the 

callback telephone number during the dial-in process. 
 
2) Remote user: 
 

If you are going to enable the Callback Security option, click on the 

Callback 

down arrow and 

choose the callback method. A fixed phone number is 

Admin specified 

or a

 

variable phone number is 

User 

specified

. For example, if a traveling sales person needs to be called back at their current location, they will 

provide the callback telephone number during the dial-in process. 
 

If the 

Callback Security 

option is enabled and 

Admin specified 

is selected, then enter their fixed 

callback telephone number in the 

Callback # 

window.  If the 

Callback Security 

option is enabled and 

User 

specified 

is selected, you 

do not 

enter a telephone in the 

callback # 

window. The remote user enters the 

callback number during the dial-in process. 
 

Note:

   The first row is for the “Administrator” function.  No matter what values are used for the Name, 

User ID and Password fields, the first row will apply to the person doing the Administrator function 
for the 102RAS.  The Administrator is the party privileged to configure the 102RAS.  

 
 

Call Log 

 
The Call Log screen displays the parameters you can set for the Call Log entries and displays a call log 
entry for each call. 
 

 

 
The Log Parameters define the threshold number of entries and the number of entries retained in the log 
history.  Both Auto Log Threshold and Log History can be set to a maximum of 20 entries by filling in the 
field and clicking on Save Changes.  The log can be E-Mailed to the Administrator address by clicking on 
Send Log Now and the Log can be deleted by clicking on Delete Log. 
 

 

 
The Call Log summarizes each call and the Details button displays an in-depth look at the call from the 
individual initiating the call, when the call was connected, duration of the call, transmit and receive baud 
rates, to authentication status. 
 

Summary of Contents for 102RAS

Page 1: ...Revised 2010 11 15 page 1 of 30 102RAS Industrial Remote Access Server User Manual Installation Guide...

Page 2: ...Features 12 Troubleshooting 13 Regulatory Statments 14 Telecom Approvals for the Embedded Modem Model Number 5634SMI 16 Software Configuration 18 Web Management 18 Web Management Home 19 Web Managemen...

Page 3: ...N Port V92 56K modem RJ 11 Rates Data V 92 56K downloads and 48K upload speeds from V 92 servers V 90 56K downloads from V 90 K56flex servers 33 6K bps transfers with other servers Standards Data V 92...

Page 4: ...ges whatsoever included but not limited to lost profits arising out of errors or omissions in this manual or the information contained herein WARNING Do not perform any services on the unit unless qua...

Page 5: ...less qualified to do so WARNING Do not operate the equipment in the presence of flammable gasses or fumes Operating electrical equipment in such an environment constitutes a definite safety hazard WAR...

Page 6: ...sified or nonhazardous locations only Package Contents Please make sure the 102RAS Remote Access Server package contains the following items 1 102RAS Remote Access Server 2 Product CD Contact your car...

Page 7: ...N rail typically it is possible to remove the unit by using your index and middle fingers or use flat head screwdrivers placed into each of the release clips at the bottom of the unit to push down on...

Page 8: ...e bottom LED indicates LINK status and the top LED indicates ACTIVITY LED s The table below describes the operating modes LED Description Lit when Power is applied LNK Lit when 10 100 Mb Link between...

Page 9: ...the Voltage Input Plug back into the Power Input Header Tightening torque for the terminal block power plug is 0 22 Nm 0 162 Pound Foot Verify the Power LED stays ON GREEN Note Only 1 power supply mu...

Page 10: ...nate users can run a drain wire lug from any of the Din Rail screws or empty PEM nuts on the enclosure When using an unused PEM nut to connect a ground lug via a machine screw care should be taken to...

Page 11: ...Revised 2010 11 15 page 11 of 30 RJ45 CONNECTOR CRIMP SPECIFICATIONS Please reference the illustration below for your Cat5 cable specifications...

Page 12: ...ble call back number each time they call The pass through option is used to provide the security of password protection while bypassing the call back process Configuration and Management The 102RAS we...

Page 13: ...tate current by 2X 3 Verify that Link LED s are ON for connected ports 4 Verify cabling used between stations 5 Verify the phone socket that the phone line from the 102RAS is plugged into is operation...

Page 14: ...five 5 0 To be certain of the number of Devices that may be connected to a line as determined by the total RENs contact the local telephone company For products approved after July 23 2001 the REN fo...

Page 15: ...mpany The equipment must also be installed using an acceptable method of connection The customer should be aware that compliance with the above conditions may not prevent degradation of service in som...

Page 16: ...of a call to another device connected to the same line 7 Some parameters required for compliance with Telecom s Telepermit requirements are dependent on the equipment PC associated with this device T...

Page 17: ...0451001 Korea Approved TE A22 K012 04 0357 Latvia Approved CE Liechtenstein Approved CE Lithuania Approved CE Luxembourg Approved CE Malta Approved CE Mexico Approved COFETEL TTDMUMT021 411 Netherland...

Page 18: ...ed 2010 11 15 page 18 of 30 Software Configuration Web Management Enter the switch s IP address in any web browser and login to the web management feature of the 102RAS Default Username admin Password...

Page 19: ...f the screen there is a list of configurable settings which the 102RAS supports This section of the manual will go through each choice listed at the top of the screen and explain how to configure thos...

Page 20: ...al Users Shows information about the Local User Database and allows User to modify Call Log Log Parameters Shows the current Logging Configuration and allows User to change Call Log Shows the Call Log...

Page 21: ...the Administration page lists the following information about the 102RAS SMTP Server Address SMTP Port Administrator E Mail SMTP Password From here you can setup the Mail Server by following the follo...

Page 22: ...y default the 102RAS receives the date and time via Time Server via an internet connection In the event the Local LAN where the 102RAS is installed does not have access to the internet you must enter...

Page 23: ...y option is enabled and Admin specified is selected then enter their fixed callback telephone number in the Callback window If the Callback Security option is enabled and User specified is selected yo...

Page 24: ...e last pending or sent e mail Time Server Status Indicates the status of the Time server which could be Initializing No Errors or SNTP Error type Up Time Operation time since last reboot E mail Status...

Page 25: ...nect Time The date and time at which the connection began for the current call Elapsed Time The duration of the current call in seconds The Administrator can also initialize the modem by clicking on I...

Page 26: ...cation User data is treated as is without interpretation and no authentication is required Modem Sharing Raw Mode with Local Authentication User data is treated as is without interpretation and a vali...

Page 27: ...number usually port 1812 for the RADIUS Server in the top Port field 3 Enter the IP address of the Radius Accounting server in the RADIUS Accounting Address 1 field 4 Enter the port number usually po...

Page 28: ...emp 20 C to 70 C Storage Temp 40 C to 85 C Operating Humidity 10 to 95 Non Condensing Operating Altitude 0 to 10 000 ft Shock and Vibration bulkhead mounting Shock 200g 10ms Vibration Seismic 50g 5 20...

Page 29: ...Class A 47 CFR Part 15 Subpart B Class A 47 CFR Part 68 Embedded Device Multi Tech Systems Model MT5634SMI EMS EN 55024 1998 w A1 A2 IEC 61000 4 2 Ed 1 2 ESD IEC 61000 4 3 Ed 2 1 RS IEC 61000 4 4 2nd...