ELECTRICAL SAFETY WARNINGS 
 

         

 

 

This equipment is suitable for use in Class I, Division 2, Groups A, B, C, and D or non-hazardous locations 
only. 
 

WARNING – 

Explosion Hazard – Substitution of components may impair suitability for Class I, Division 2. 

 

WARNING – 

Explosion Hazard – Do not disconnect while circuit is live unless area is known to be non-

hazardous. 
 

WARNING – 

Explosion Hazard – Do not replace the device unless power has been switched off or the area is 

known to be non-hazardous. 
 
Use 60/75°C rated copper wire, (0.22Nm) 2 lb/in tightening torque for field installed conductors. 
 

WARNING:     

Do  not  operate  the  equipment  in  the  presence  of  flammable  gasses  or  fumes.    Operating 

electrical equipment in such an environment constitutes a definite safety hazard. 

 
WARNING:   

If the equipment is used in the manner not specified by N-TRON Corp., the protection provided 

by the equipment may be impaired.

  

 
WARNING:   

Do  not  perform  any  services  on  the  unit  unless  qualified  to  do  so.    Do  not  substitute 

unauthorized parts or make unauthorized modifications to the unit. 

 
WARNING:

 Properly ground the unit before connecting anything else to the unit.  Units not properly grounded 

may result in a safety risk and could be hazardous and may void the warranty.  See the grounding technique 
section of this user manual for proper ways to ground the unit. 
 

WARNING:     

Do  not  operate  the  unit  with  the  end  plates  removed,  as  this  could  create  a  shock  or  fire 

hazard. 

 
WARNING:   

Do not operate the equipment in a manner not specified by this manual. 

 

WARNING: 

Do not work on equipment or cables during periods of lightning activity. 

 

WARNING:

 Observe proper DC Voltage polarity when installing power input cables.  Reversing voltage 

polarity can cause permanent damage to the unit and void the warranty. 

WARNING:

  Install only in accordance with Local & National Codes of Authorities Having Jurisdiction. 

 
 
 
 
 
 
 

Summary of Contents for 100-POE-SPL

Page 1: ...Revised 2010 11 15 1 100 POE SPL Industrial Power Extractor User Manual Installation Guide...

Page 2: ...tractor Installation Guide 100 POE SPL XX Unmanaged Industrial PoE Power Extractor Where XX is 12 for 12VDC output voltage option 24 for 24VDC output voltage option 48 for 48VDC output voltage option...

Page 3: ...ion contained in this document is subject to change without notice N TRON Corp makes no warranty of any kind with regard to this material including but not limited to the implied warranties of merchan...

Page 4: ...TRON Corp the protection provided by the equipment may be impaired WARNING Do not perform any services on the unit unless qualified to do so Do not substitute unauthorized parts or make unauthorized m...

Page 5: ...Cat5e cable connected to a PoE sourcing device The 100 POE SPL allows legacy devices which are not PoE capable to be deployed without the need to provide a dedicated power supply The 100 POE SPL can b...

Page 6: ...emove all the equipment from the packaging and store the packaging in a safe place File any damage claims with the carrier CLEANING Clean only with a damp cloth INSTALLATION Read the following warning...

Page 7: ...unit from the 35mm industrial DIN rail pull forward on the unit until it disengages from the bottom of the DIN rail Rotate the bottom of the unit towards you and up at an approximate 15 upward angle...

Page 8: ...48VDC connector Model dependent Green LED lights when Power is present POE IN RJ45 connector for data and PoE in DATA OUT RJ45 connector for data only out LEDs The table below describes the operating...

Page 9: ...ource device into the POE IN port Verify the Power LED stays ON GREEN Note Either V1 or V2 can be connected to power for minimal operation For redundant power operation V1 and V2 plugs must be connect...

Page 10: ...gative output terminal and the chassis grounding point of the switch As an alternative grounding method both V legs of the power input connector are connected to chassis internally on the PCB Connecti...

Page 11: ...voltage to 12 24 48VDC for the legacy end device Warning The 100 POE SPL XX is not a switch and will not actively boost the Ethernet signals So the total max segment length is a combined 100meters Mea...

Page 12: ...cause harmful interference in which case the user will be required to correct the interference at his own expense INDUSTRY CANADA This Class A digital apparatus meets all requirements of the Canadian...

Page 13: ...DC Max Full Load Output Wire Size 16 28 AWG Max Capacitive Load 400uF Assuming 50ohm DC Load Max Inrush 700mA 50ms 24VDC Environmental Operating Temperature 40 C to 85 C Storage Temperature 40 C to 85...

Page 14: ...2 Groups A B C D hazardous or non hazardous locations temperature code of T4 EMI EN61000 6 4 EN55022 Class A FCC Title 47 Part 15 Subpart B Class A ICES 003 Class A EMS EN61000 6 2 EN61000 4 2 ESD EN6...

Page 15: ...RANTIES EXCLUSIVE IF AN N TRON PRODUCT DOES NOT OPERATE AS WARRANTED ABOVE CUSTOMER S SOLE REMEDY FOR BREACH OF THAT WARRANTY SHALL BE REPAIR REPLACEMENT OR REFUND OF THE PURCHASE PRICE PAID AT N TRON...