![N.KO B5 Operation Manual Download Page 4](http://html2.mh-extra.com/html/n-ko/b5/b5_operation-manual_3075545004.webp)
4
Specifications
Motor voltage:
230 volts, 50/60Hz
110V for other countries
Power:
1.300 W
Speed:
4.200 to 11.000min
-1
with soft start, including thermo protection and overload limiter
Feed:
manual
Feed rate:
1-4 m/min, dependant on chamfer width and material quality
Bevel Height and Width
The bevel width is calculated using the following equation: B = H x 1.414
Material and
Chamfer Width (2) mm
6
0°
45°
Tensile Strength
230V
230V
Steel 400 N/mm²
4
5
Steel 600 N/mm²
3
3
Stahl 800 N/mm²
2
2
Aluminium 250 N/mm²
6
6
Adjusting the bevel width and height
The bevel height can be adjusted using the support plate and is metered by means of the marker on the graduated
collar.
1 = Support plate.
2 = Knurled nut.
3 = Adjusting collar.
4 = Scale.
5 = upper limitation stone
a) Loosen knurled screw (2).
b) Turn support plate (1) until desired bevel height is achieved on graduated collar. The line markings on the scale
indicate the approximate bevel height in millimetres (one marking line is approx. 1mm). Use the markings on the
adjusting collar for fine adjustment. The distance from one marking line to the next corresponds to approx. 0.05mm
of chamfer height.
c) Tighten knurled screw (2).
d) The upper limitation stone (5) limited the bevel width