Figure 18
–
Installing FMC Module Part 2
6.4.
FMC EEPROM Wizard
Per default, the carrier will try to parse the FMC FRU records from the modules EEPROM
contents to set the carrier’s power supply and clock direction. In case there is an FMC without
records, there are two options:
1)
Generate and program the records with the carrier. Set SW2-3 2
to “ON”.
2)
Ignore the FRU EEPROM. This is automatically done when no valid FRU content is
detected.
Warning:
In this case, a default VADJ voltage of 1.8V is applied to the FMC module.
Please check the capabilities of your FMC in this case.
In case the records for the FMC should be generated with the carrier, the Micro USB cable has
to be connected to the front plate’s USB port. The host should detect a USB
-Hub and two COM
ports. The first enumerated COM port is the serial console of the MMC. Open it with a tool
(e.g. TeraTerm) and set the COM settings according to the following figure.
Figure 19
–
Serial Console COM Port Settings