Aution: Protection Functions 

 

1.

 Over charged protection 

                             

 

        2.

 Current protection

 

3.

 Shortage protection( fuse installation)             

   

4.

 Battery reverse current protection 

5.

 Built-in ID recognition feature protection           

6. 

Temperature protection   

 

(1)

 

When the battery temperature is between 0-10

, the charger will use low current to   

pre-charge the battery until the battery temperature higher then 10

 , then the charger switch back to 

normal charging mode. When the battery temperature is below 0

, the charger will stop charging 

the battery until the battery temperature is higher then 0

(2)

 

When the battery temperature is above 45

, the charger will automatically change to low   

current to charge the battery. When the battery temperature is exceed 50

, the charger will stop 

charging the battery and make warring beep sound until the battery temperature drop down back to 
40

 , then the charger switches back to normal charging mode. 

(3)When the charger temperature rises to 75

, the charger will trigger protection mechanism to stop 

charging the battery and until the charger temperature drop down back to 65

 , then the charger 

switches back to normal charging mode. 
7.When the charger detects the battery temperature is lower 0

 or about 50

, then the charging process 

will be stopped. Automatically rechargeable   
8.Low power protection: when the battery voltage is lower than 15V, the charger will automatically 
change to low current to pre-charge the battery and until the battery voltage is reach to 15V, then the 
charger switches back to fast charging mode. 
 

Specifications 

 

Model type 

Automatic Cordless Screwdriver Battery Charge Station   

MYCS-ID120 

Charge Station 

Input voltage (AC) 

100V – 240V/0.5A~1.2A 

Output 

voltage(DC) 

21VDC 

Output current 

4.5A 

3.0A 

Charge time 

(SKC-LB1840) 

About 35 min charge to 80% and 45 

min to fully charged 

(SKC-LB1820) 

About 25 min charge to 80% and 30 min 

to fully charged 

Battery capacity 

(3900 mA/hr) 

(1950mA/hr) 

Battery type 

Lithium-ion rechargeable battery 

Battery ID 

configuration 

Battery capacity indicator to show the battery current capacity 

Battery ID identifier to match the Kilews’ battery before charging. 

size 

W × L × H    160mm×170mm×80mm 

Weight 

1.1Kg 

 

Caution 

SAVE THESE INSTRUCTIONS 

DO NOT DESTROY 

 

 

Summary of Contents for MYCS-ID120

Page 1: ...OPERATION MANUAL FOR CHARGE STATION MYCS ID120 In AC 100 240V Out 21V ANLIDAR INDUSTRIAL CO LTD http www anlidar com Y2F109 2E 001 ...

Page 2: ...nder sun high temperature high humidity and highly explosive gas 6 Do not place charger on high shelf The charger should be placed on the leveled firmed spot that prevent children from reaching 7 Do not abuse the cord Never use the cord to carrying pulling or unplugging the charger Keep cord away from heat oil sharp edges or moving parts Damaged or entangled cords increase the risk of electric sho...

Page 3: ...of battery or for other propose 7 Please do not attempt to disassemble or modify the charger and the rechargeable battery Operation Instruction 1 Please check the cord to see if there any damage before plug in the charger Hold the plug of power cord while plugging in or unplug the charger 2 Do not place chargers near oil chemical materials or heated objects also please be alert not to scratch the ...

Page 4: ...reen lights both are blinking with continuous short beep sounds means there are errors when charging the battery Check for the battery if the battery insert correctly If the charger continues shows error please change another batter to see if the error was caused by battery or the charger This charger only applies to the rechargeable battery of Kilews Please do not apply the charger to other diffe...

Page 5: ... the current selected language There have two language for selection 1 EN B Press button B to select English 2 中文 L Press button L to select Chinese is the current selected language Press button B for 5 seconds to select English language when setting is completed the status line will display Set Completed Press button L for 5 seconds to select Chinese language when setting is completed the status ...

Page 6: ...rger Information and Buzzer Status Description Charger Status Buzzer Status BATT ID Correct Beep 1 sec Normal B VOLT FULL Beep 3 sec Normal BATT FAIL Beep 1 sec Continue Abnormal B TEMP HIGH Beep 1 sec Continue Abnormal B TEMP OVER Beep 1 sec Continue Abnormal C TEMP LOW Beep 1 sec Continue Abnormal C TEMP HIGH Beep 1 sec Continue Abnormal BATT ID ERROR Beep 1 sec Continue Abnormal BATT OK Ready t...

Page 7: ...to stop charging the battery and until the charger temperature drop down back to 65 then the charger switches back to normal charging mode 7 When the charger detects the battery temperature is lower 0 or about 50 then the charging process will be stopped Automatically rechargeable 8 Low power protection when the battery voltage is lower than 15V the charger will automatically change to low current...

Page 8: ...ATERIAL DES BY CHKD BY APPD BY SHRINK DATE DATE DATE PRODUCTION NO THIRD ANGLE PROJECTION UNIT SCALE SHT NO OF SHTS 零件 編號 排插圖示 排插 位置 3 2 9 1 13 1 3 1 14 1 3 2 13 1 14 1 9 17 11 1 1 7 8 4 3 2 3 1 9 1 1 1 16 13 13 1 14 14 1 18 12 15 15 5 5 10 6 1 2 MODEL NO MYCS ID120 ...

Page 9: ... ...

Page 10: ... ...

Reviews: