6.

 

LCD Screen and LED Light Display Description   

   

 

 

 

 

 

 

 

 

                                                                                                                                                                                           

                                                                                                                                                                                                 

 

 

                                                                                                             

 

 

 

 

(1) When the charger plug in the power, it starts automatically. (The following lists are   
          charger start sequence.) 

1.

 

Light Display shows continuous green light 

 

2.

 

One long beep sounds 

 

3.

 

Fan start and then stop   

(2) Red light flash => means the battery is charging.   

 

(3) Long yellow light and flash red light=>means the battery is charged 80% and continuous   
          charging. 

 

(4) Red and green lights both light up at the same time=>means the battery is fully charged 100% and 

one long beep sound for 3s. 

(5) Red and green lights both are blinking=>with continuous short beep sounds means there are errors 

when charging the battery. Check for the battery if the battery insert correctly. If the charger 
continues shows error, please change another batter to see if the error was caused by battery or 
the charger.

 

This charger only applies to the rechargeable battery of Kilews. Please do not apply 

the charger to other different brand of battery.   

(6) Battery status: Press (B) button for 5 seconds to switch the screen to “Battery Charge Status   

          Display” 

 

Counter status 

 

 
 
 
 
 
 
 
 
 
 
 

 

 

 

 

Chinese Mode Display 

English Mode Display 

 

 

Screen Display Description 

LINE 1 

Total charaged times 

LINE 2 

Total charaged hours 

LINE 3 

Total charaged minutes 

Light Display 

1

 

2

 

3

 

4

 

5

 

6

 

7

 

Light Display 

Summary of Contents for MYCS-ID120

Page 1: ...OPERATION MANUAL FOR CHARGE STATION MYCS ID120 In AC 100 240V Out 21V ANLIDAR INDUSTRIAL CO LTD http www anlidar com Y2F109 2E 001 ...

Page 2: ...nder sun high temperature high humidity and highly explosive gas 6 Do not place charger on high shelf The charger should be placed on the leveled firmed spot that prevent children from reaching 7 Do not abuse the cord Never use the cord to carrying pulling or unplugging the charger Keep cord away from heat oil sharp edges or moving parts Damaged or entangled cords increase the risk of electric sho...

Page 3: ...of battery or for other propose 7 Please do not attempt to disassemble or modify the charger and the rechargeable battery Operation Instruction 1 Please check the cord to see if there any damage before plug in the charger Hold the plug of power cord while plugging in or unplug the charger 2 Do not place chargers near oil chemical materials or heated objects also please be alert not to scratch the ...

Page 4: ...reen lights both are blinking with continuous short beep sounds means there are errors when charging the battery Check for the battery if the battery insert correctly If the charger continues shows error please change another batter to see if the error was caused by battery or the charger This charger only applies to the rechargeable battery of Kilews Please do not apply the charger to other diffe...

Page 5: ... the current selected language There have two language for selection 1 EN B Press button B to select English 2 中文 L Press button L to select Chinese is the current selected language Press button B for 5 seconds to select English language when setting is completed the status line will display Set Completed Press button L for 5 seconds to select Chinese language when setting is completed the status ...

Page 6: ...rger Information and Buzzer Status Description Charger Status Buzzer Status BATT ID Correct Beep 1 sec Normal B VOLT FULL Beep 3 sec Normal BATT FAIL Beep 1 sec Continue Abnormal B TEMP HIGH Beep 1 sec Continue Abnormal B TEMP OVER Beep 1 sec Continue Abnormal C TEMP LOW Beep 1 sec Continue Abnormal C TEMP HIGH Beep 1 sec Continue Abnormal BATT ID ERROR Beep 1 sec Continue Abnormal BATT OK Ready t...

Page 7: ...to stop charging the battery and until the charger temperature drop down back to 65 then the charger switches back to normal charging mode 7 When the charger detects the battery temperature is lower 0 or about 50 then the charging process will be stopped Automatically rechargeable 8 Low power protection when the battery voltage is lower than 15V the charger will automatically change to low current...