
SPEEDSTER
1003Dx
MYTEE PRODUCTS, INC | 13655 STOWE DRIVE | POW
AY. CA
92064
PHONE: 858-679-1191 | F
AX: 858-679-7814
WWW.MYTEE.COM
WARRANTY
Mytee Products, Inc. endeavors to provide high quality products and product support to its customers and therefore backs up
a
ll of its new products purchased from Mytee Products Inc. (“Mytee”) or any authorized Mytee distributor/service center
with this limited warranty. This limited warranty begins on the date of the customer
’s purchase and is valid and avail
-
able to the original purchaser only. Mytee’
s products are for commercial use only and are not intended for personal,
family or household uses.
HOWEVER, OTHER THAN SET FORTH HEREIN, MYTEE GIVES NO WARRANTY
, EXPRESS OR IMPLIED, AS T
O DESCRIP-
TION, QUALITY, MERCHANT
ABILITY, FITNESS FOR
ANY P
ARTICULAR PURPOSE, PRODUCTIVENESS, INFRINGEMENT,
OR OTHER MATTER, OF
ANY GOODS WHICH MYTEE SHALL
SUPPLY. THERE
ARE NO WARRANTIES WHICH EXTEND
BEYOND THE DESCRIPTION ON THE FACE HEREOF
. MYTEE SHALL IN NO W
AY BE RESPONSIBLE FOR THE PROPER
USE AND
APPLICATION OF THE GOODS. MYTEE NEITHER
ASSUMES NOR AUTHORIZES
ANY OTHER PERSON T
O
ASSUME FOR MYTEE ANY
OTHER LIABILITY IN CONNECTION WITH THE SALE OF MYTEE’S GOODS. THIS LIMITED
WARRANTY
POLICY MA
Y BE CHANGED OR WITHDRA
WN BY MYTEE
AT
ANY TIME WITHOUT NOTICE
.
WEAR PARTS 90-DA
Y LIMITED W
ARRANTY: Mytee will replace all wear parts for 90 days from the date of original pur
-
chase. “Wear parts” are items which wear out as a result of usage or the passage of time and are consumed despite
attempts to maintain them, such as gaskets, wheels, brass, cords, wires, electrical terminals, hoses, switches, ther-
mostats, plastisol parts, filters, bearings, brushes, solenoids, o-rings, bulbs, heating elements, castors, or other parts
deemed wear items in Mytee’s sole discretion. This warranty covers the cost of replacement only and does not cover
shipping or labor costs.
PUMP, V
ACUUM MOTOR
AND HEATER 1-YEAR LIMITED W
ARRANTY: Mytee warrants that pumps, vacuum and floor
machine motors, and heaters will be free from manufacturing defects, defects in workmanship, and defects in material
for one (1) year from the date of original purchase. This warranty does not apply and is void if the pump, vacuum motor,
or heater has worn brush motors, water damage, chemical build-up, chemical damage, or evidence of abuse, neglect or
tampering. This warranty covers the cost of replacement or repair only and does not cover shipping or labor costs.
HOUSING 5-YEAR LIMITED WARRANTY
: For five (5) years from the date of purchase, Mytee warrants a percentage of the
cost of replacement of rotationally-molded housings pro-rated as follows: Mytee will pay 100% of replacement cost in
the first year from the date of purchase, 75% of replacement cost in the second year from the date of purchase, 50% in
the third year, 25% in the fourth year
, and 12% in the fifth year. Replacement cost does not include the cost of shipping
or labor.
LIMITATION OF DAMAGES: THE REMEDY
OF REPLACEMENT OR REPAIR OF
ANY DEFECTIVE GOODS SHALL
BE THE
EXCLUSIVE REMEDY UNDER
ANY W
ARRANTY MADE BY
MYTEE, WHETHER EXPRESS OR IMPLIED. IN NO EVENT
SHALL MYTEE BE LIABLE FOR
ANY INCIDENT
AL OR CONSEQUENTIAL
DAMAGES, PROPERTY DAMAGES, OR PER
-
SONAL INJURIES.
All limited warranties are void for, and Mytee does not warrant in any way
, any product that evidences misapplication,
improper installation, abuse, lack of maintenance, negligence in use or care, abnormal use, alteration of design, use of
incompatible or corrosive chemicals, use in a rental service, and/or servicing, installation of parts, or repairs by anyone
other than Mytee or a Mytee authorized distributor or service center.
Mytee may make changes in products it manufactures and markets at any time; these changes are made without obliga-
tion to change, retrofit, or upgrade any product previously sold or manufactured. Mytee has no obligation to honor the
limited warranties set forth herein unless the original purchaser, promptly upon discovering the warranty claim and
prior to continuing to use the product, contacts Mytee or a Mytee authorized distributor or service center to describe
the claim and to receive and follow instructions for documenting and resolving the claim. In addition, the purchaser
must provide the product to which the claim applies to Mytee or a Mytee authorized distributor or service center for a
thorough inspection.
If any provision or portion of this limited warranty policy is found to be unenforceable, then the remaining provisions
and portions shall remain valid and enforceable. If any provision or portion of this limited warranty policy is found to
be limited by law, then that provision or portion shall be construed to make it effective within the bounds of law
. For ex-
ample, if there are legal limitations on the duration of warranties, the warranties made herein shall be construed to have
the minimum duration required by law, or
, if there are legal limitations of exclusion of remedies, the exclusions made
herein shall be construed to apply to the fullest extent possible without violating the law.
The validity, construction and performance of this warranty policy shall be governed by the laws of the State of Califor
-
nia, without respect to conflicts of laws principles. The exclusive jurisdiction of any legal action arising from or related
to this warranty policy shall be in the State of California and no legal action shall be commenced elsewhere.
UNPACKING THE MACHINE
Before unpacking the machine, inspect all boxes and pallets for signs of shipping damage.
Please be aware that all packages leave Mytee Products in perfect condition. Any equipment or
carton damage caused during shipping is the responsibility of the freight company, and should
be handled by filing a claim with the carrier.
H375 - Hose Hanger
E530 - (2) 12/3 50’
Yellow Safety Cord
H226 - 45O Drain Elbow
Speedster Extractor
SAFETY LABELS
The safety labels
appear on the
machine in the
locations indicated.
Replace labels if they
become damaged or
cannot be read.
WARNING: Flammable materials can cause an
explosion or fire. Do not use flammable materials in
tank(s). Flammable materials or reactive metals can
cause explosion or fire.
WARNING LABEL- Located on back. Label warns
operator of safe practices of equipment.
MACHINE COMPONENTS
Recovery
Tank
Solution
Tank
Motor
Housing/
Base
Vacuum
Hose
Connector
Solution
Hose
Connector
Pressure
Regulator
Prime Valve
SETUP
1. Open lid of solution tank. Fill solution tank with
water or approved cleaning agent.
WARNING: Flammable materials can cause an
explosion or fire. Do not use flammable solutions or
materials in tank(s).
FOR SAFETY: When using machine, follow mixing
and handling instructions on chemical containers.
ATTENTION: If using powdered cleaning chemicals,
mix prior to adding.
2. Attach solution hose. (Located front of machine.)
NOTE: Make sure the quick disconnects snap
together firmly. As you do this, always inspect
hoses for cracks or fraying. Do not use if hoses are
damaged.
3. Attach other end of solution hose to wand.
4. Attach vacuum hose to recovery tank.
5. Plug machine’s cord into a grounded wall outlet.
FOR SAFETY: Do not operate machine unless cord is
properly grounded.
FOR SAFETY: Do not operate machine with the use
of an extension cord.
PRE-OPERATION
1. Vacuum carpet and upholstery and remove
other debris.
2. Perform MACHINE SETUP procedures.
3. Inspect power cord for damage.
OPERATION
7. Turning machine on.
A. Turn pump switch on.
B. Pull up on power prime lever for 30 seconds.
This will prime the pump.
C. Pull up on wand lever to release air in the
line. Hold lever until you have a steady flow of
water coming out of the wand.
D. Once pump is primed and you have pressure
in the solution line, turn on heater switch(s) (if
model is equipped with heater) and wait a few
minutes for water to heat up.
E. Once water is heated, turn on vacuum
motors and begin cleaning.
NOTE: When cleaning upholstery, always check
manufacturer’s cleaning instructions.
DRAINING RECOVERY TANK
FOR SAFETY: When servicing machine, unplug cord from
wall outlet.
1. Turn machine off and unplug power cord.
2. Remove solution & vacuum hose.
3.Attach 45º-drain elbow to dump valve and lift up drain
valve lever to empty recovery tank.
TIPS
1. Work away from outlet and power cord to prevent cord
damage.
2. Use a recommended foam control solution in the
recovery tank to prevent vacuum motor damage.
Periodically check for excessive foam buildup in solution
tank, and recovery tank.
3. To clean heavily soiled areas, repeat cleaning path from
different direction.
4. When ball float shuts off vacuum, it is time to empty the
dirty water from the recovery tank, and refill solution tank.
5. After cleaning, relieve water pressure from tool before
disconnecting hose. Squeeze trigger for five seconds
after turning main power switch off.
MAINTENANCE
MACHINE MAINTENENCE
To keep machine in good working condition, simply follow
machine’s daily and weekly maintenance procedures.
Check valves and relief valves should be replaced
annually.
FOR SAFETY: When servicing machine, unplug cord from
wall outlet.
DAILY MAINTENANCE
1. Empty and rinse out solution tank thoroughly.
2. Wipe off power cord and check for damage, replace if
necessary. Coil cord neatly after use.
3. Clean machine with an all purpose cleaner and damp cloth.
WEEKLY MAINTENANCE
(EVERY 20 HOURS OF OPERATION)
1. Flush solution system with Mytee system
maintainer to dissolve normal chemical buildup.
a. Pour 7.5L (2 gal) of hot water 60°C
(140°F) into solution tank. Add Mytee
system maintainer according to mixing
instructions on bottle
FOR SAFETY: When using machine, follow
mixing and handling instructions on chemical
containers.
b. Operate machine for one minute.
c. Shut off machine and allow remaining
solution to break down chemical buildup
overnight.
d. Next day, spray out remaining
solution and flush system with 11L (3gal)
of clean water.
2. Inspect vacuum hoses for holes and loose
cuffs. Drain and dry the vacuum hose as well.
3. Inspect spray pattern for clogging. If
clogged, remove spray tips and soak them in
a recommended liquid neutralizer for up to six
hours. To remove spray tip, twist spray tip body
counter-clockwise.
4. Lubricate wheels with water resistant oil.
5. Inspect machine for water leaks and loose
hardware.
6. Remove float shut-off screen from recovery
tank and clean.
NOTE: The float shut off screen is not glued on.
Simply pull it off.
STORING MACHINE
1. Before storing machine, be certain to
completely drain and rinse tanks of all water and
solution.
2. Drain and dry the vacuum hose as well, using
the drain hose provided
3. Store machine in a dry area in the upright
position.
4. Open recovery tank cover to promote air
circulation
ATTENTION: Do not expose to rain. Store indoors.
ATTENTION: If storing machine in freezing
temperatures, be sure that machine and solution
system are completely drained and dry.
!
!
!
Instruction Manual
& Safety Guide