Important Information

    

03

BEFORE YOU BEGIN

SAFETY PRECAUTIONS

Radiators are hot when in use, and as such, present a risk of burns to users on prolonged contact. The temperature of a
radiator is dependent on the temperature of the system water, as set by the system installer or user. Installers and users
should ensure  that  those  who  may  come  into  close  proximity  to  hot  radiators  are  aware  of  the  risk  of  burns.  Installers
and users should take all necessary steps to minimise the risks of burns. If the risk is significant, consideration should be
given to installing low surface temperature radiators, or to placing guards in front of the radiators.

For  the  correct  installation  of  radiators  it  is  essential  that  the  fixing of the radiator is carried out in such a way
that  it  is  suitable  for  intended  use  AND  predictable  misuse.  A  number  of  elements  need  to  be  taken  into
consideration including the fixing method used to secure the radiator to the wall, the type and condition of the wall
itself,  and  any  additional  potential  forces  or  weights  that  may  happen  to  be  applied  to  the  radiator,  prior  to
finalising  installation.

 

IN  ALL  CASES  IT  IS  STRONGLY  RECOMMENDED  THAT  A  SUITABLY  QUALIFIED

PROFESSIONAL INSTALLER OR SIMILAR TRADESPERSON CARRIES OUT THE INSTALLATION.

INTRODUCTION

The Myson 

Column

 Radiator will keep any room in comfort and style. We at Myson Inc. thank you for your purchase of the 

Column

 Radiator. Each radiator combines Myson’s compact design and advanced steel construction with a durable baked 

epoxy/polyester  enamel  powder  coat  finish.  Myson’s  sleek  styling  and  thorough  testing  provides  attractiveness  and

 

dependability. Myson’s goal is to assure the highest performance, quality, reliability and outstanding customer service.

CAUTION

Step 1

 

Read this entire instruction manual thoroughly before beginning installation.

Step 2

 

To ensure full efficiency of your Myson Décor Steel Panel Radiator, please follow all 

the instructions carefully .

Step 3

 

Failure to follow these instructions will invalidate the manufacturer’s warranty.

APPLICATION

Myson radiators are only for use in recirculating closed loop hydronic-heating systems. These radiators are not recom

-

mended 

 

for gravity systems. 

 

DO NOT USE STEAM IN THESE RADIATORS.

INSPECT FOR DAMAGE
NOTE: 

Inspect materials for concealed shipping damage. You only have 10 days to file a freight claim. If items are 

damaged or missing, please call Myson at 1-800-698-9690.

INSPECTION FOR COMPLETENESS

Unpack the radiator carefully to avoid damage or loss of parts. 

The 

Column

 

R

adiator will come with the following parts:

• Wall 

mounting 

bracket

 kit

• Plastic inserts for noise suppression
• Stainless steel solid plug
• Vent plug

IT IS STRONGLY RECOMMENDED THAT A SUITABLY QUALIFIED PROFESSIONAL
INSTALLER OR SIMILAR TRADESPERSON CARRIES OUT THE INSTALLATION.

Myson products are designed to be installed by professional tradespeople. Myson instructions are meant to be thorough; 
however it is assumed that the installer has the appropriate technical knowledge related to building codes, standard trade 
practices, and proper use of the tools of the trade. Should a homeowner without such knowledge or skill take it upon him/
herself to attempt the installation, Myson will not be responsible for any damages, injuries or unsatisfactory performance of the 
Myson product used.

DESIGN AND LAYOUT CONDITIONS

Myson 

Column

 Radiators should only be used with a 

properly sized 

recirculation pump 

closed loop hydronic heating system

Please consult national and local codes for specific restrictions that may be imposed on your installation. Position your radiator 
away from your

 

circulator pump to avoid either excess pressure that could force water out the air vent or excess suction that 

could  draw  air  into  the  system.  The  preferred  positioning  for  the 

Column

  radiator  is  below  a  window  where  it  can  minimize 

downdrafts from glazed areas.

Myson Inc./Rettig USA  45 Krupp Drive, P.O. Box 1460,  Williston,  VT 05495  www.mysoncomfort.com

Summary of Contents for BENCH

Page 1: ...01 11 2011 MYSON heatingthroughinnovation Column Radiator Series Installation Technical Guide...

Page 2: ...competent technician with knowledge of hydronic heating and or basic electricity Damages occurring during shipment transit storage or handling abuse neglect accident misapplication incorrect power lin...

Page 3: ...son D cor Steel Panel Radiator please follow all the instructions carefully Step 3 Failure to follow these instructions will invalidate the manufacturer s warranty APPLICATION Myson radiators are only...

Page 4: ...pressure 145 psi Maximum operating temperature max 72psi max 04 Myson Inc Rettig USA 45 Krupp Drive P O Box 1460 Williston VT 05495 www mysoncomfort com P R O D U C T D E S C R I P T I O N 12 3045 Ove...

Page 5: ...e 12 for additional valve choices DAV12 4 3 4 1 3 16 2 5 16 3 1 4 5 8 2 1 2 Position 2 Position 1 Column Radiator Wall Brackets 4 Column 5 1 2 3 Column 4 2 Column 2 1 2 Pipe centers from finished wall...

Page 6: ...radiator valves are available for automatic temperature control of individual radiators available in 3 body patterns with or without thermostatic head sensor use in conjunction with LKD or FF Myson In...

Page 7: ...ow 25 32 13 16 7 16 3 4 1 1 2 15 32 Wall Bracket Wall Radiator A Distance between Wall Center Wall Bracket Radiator Bracket 25 32 7 16 17 32 21 2 31 4 4 13 16 7 16 1 5 8 27 8 3 5 8 43 8 2 column 3 col...

Page 8: ...for top of upright Height of Upright Order Code 18 24 30 Base Plate Cover Height of Radiator 12 18 24 50 20046 50 20061 50 20076 COVERSK Floor Bracket SK Optional COLUMN Floor Bracket Detail 49 16 Mys...

Page 9: ...12 6 41 4 3006 6 2200 16 8 55 2 4008 8 2200 20 10 69 0 5010 10 2200 24 12 82 8 6012 12 2200 30 15 103 5 7515 15 2200 Water Content gals 1 68 2 24 2 80 3 36 3 92 5 00 2 10 2 80 3 50 4 20 4 90 3 00 4 0...

Page 10: ...80 85 x 21 x 14 6 190 9182 23 06 6180 93 x 19 x 14 5 186 8895 23 05 6200 Water Content gals 3 75 4 49 4 41 5 28 4 52 6 50 5 34 7 64 5 90 Dimensions in LxHxW 93 x 21 x 14 6 205 10383 23 06 6200 8 42 3...

Page 11: ...nc Rettig USA 45 Krupp Drive P O Box 1460 Williston VT 05495 www mysoncomfort com 11 The following drawings are general examples Consult a certified heating professional for your specific application...

Page 12: ...andles FF16WAC is adjustable for balancing FF16LAC is fixed open but can be closed for service TRV thermostatic radiator valves are available for automatic temperature control of individual radiators...

Page 13: ...esh water oxygen into the system attacking radiators internally SYSTEM START UP MAINTENANCE CLEANING 1 Once operating avoid the introduction of fresh water and oxygen to the system to prevent corrosio...

Page 14: ...NOTES Notes Myson Inc Rettig USA 45 Krupp Drive P O Box 1460 Williston VT 05495 www mysoncomfort com 14...

Page 15: ...NOTES Notes Myson Inc Rettig USA 45 Krupp Drive P O Box 1460 Williston VT 05495 www mysoncomfort com 15...

Page 16: ...heatingthroughinnovation MYSON Myson Inc Rettig USA 45 Krupp Drive P O Box 1460 Williston VT 05495 www mysoncomfort com COLUMN 3 2014...

Reviews: