Installation
Manual No. 775064
2-13
2.
Termination - Both Internal and External Devices
Check that the drive channel is properly terminated according to the
drawing below.
If the controller is in the middle of the SCSI bus, it automatically
disables
on-board termination. If some SCSI devices on the channel are
connected to the internal connector,
and
some are connected to the
external connector,
on the same channel, the two ends of the SCSI bus
farthest from the controller must each be terminated.
See Figure 2-11 for an example of a combined internal and external
drive configuration. Notice that they are on the same channel.
☛
Note
It is better to terminate the ends of the SCSI bus itself
than it is to terminate the end devices on the bus. This
allows hot swap devices to be added or removed from
the SCSI bus without affecting termination.
☛
Note
The only devices controlled by the RAID
configuration are the ones physically
connected to the AcceleRAID 170 controller.
Figure 2-11. Termination with Internal and External Drive Configuration
3. Remove or set disk drive termination jumpers to the
disabled
position
(if needed). Refer to the documentation furnished with your disk drives
to determine if your termination jumpers need to be adjusted.
Summary of Contents for AcceleRAID 170
Page 1: ......
Page 2: ......
Page 10: ...viii AcceleRAID 170 Installation Guide...
Page 16: ...User supplied Items 1 6 AcceleRAID 170 Installation Guide...
Page 38: ...In Case of Problems 3 6 AcceleRAID 170 Installation Guide...
Page 44: ...System Reboot or Power Down B 4 AcceleRAID 170 Installation Guide...
Page 55: ...Regulatory Information Manual No 775064 E 5 Underwriters Laboratories Statement and Warning...
Page 56: ...Underwriters Laboratories Statement and Warning E 6 AcceleRAID 170 Installation Guide...
Page 82: ......
Page 85: ......
Page 86: ......