background image

20  |

|  21

INSTRUCTION

MANUAL FOR MODELS

Model identifier(s): MHPH05-10E

P

Manual heat charge control, with integrated 

thermostat

Manual heat charge control with room 

and/or outdoor temperature feedback

Electronic heat charge control with room 

and/or outdoor temperature feedback

Fan assisted heat output

Two or more manual stages, no room 

temperature control

With mechanic thermostat room temperature 

control

With electronic room temperature control

Electronic room temperature control plus 

day timer

Electronic room temperature control plus 

week timer

Room temperature control, with presence 

detection

Room temperature control, with open 

window detection

With distance control option  (WiFi Option)

Minimum heat output 

(indicative)

Maximum continuous 

heat output

At nominal heat 

output

At minimum heat 

output

In standby mode

Item

Item

Unit

Symbol

Value

Heat output

Type of heat input, for electric storage local space 

heaters only (select one)

Auxiliary electricity 

consumption

Other control options (multiple selections 

possible)

1.0

With adaptive start control

With working time limitation

Information requirements for electric local space heaters

nom

kW

P

min

P

max,c

el

max

el

min

el

sb

1.0

1.0

No

No

0.00061

[no]

[no]

[no]

[no]

Unit

Nominal heat output

kW

kW

kW

kW

kW

With black bulb sensor

[no]

[no]

[no]

[no]

[no]

[no]

[yes]

[yes]

[yes]

[no]

[no]

[no]

Contact details

Hygiene Supplies Direct Limited, Ground floor, 

Tayson House, Methley Road, Castleford WF10 1PA

Model identifier(s): MHPH05-15E

P

Minimum heat output 

(indicative)

Maximum continuous 

heat output

At nominal heat 

output

At minimum heat 

output

In standby mode

Item

Symbol

Value

Heat output

Auxiliary electricity 

consumption

1.5

nom

kW

P

min

P

max,c

el

max

el

min

el

sb

1.5

1.5

No

No

0.00061

Unit

Nominal heat output

kW

kW

kW

kW

kW

Type of heat output/room temperature control 

(select one)

Single stage heat output and no room 

temperature control

| MAINTENANCE

1.  Always disconnect the appliance and let it completely cool before any maintenance.

2.  Use a vacuum cleaner to remove dust on grilles.

3.  Clean the outside of the unit with a damp cloth and then dry it with a dry cloth. Never 

immerse the unit in water, nor let water drip into the unit. 

| STORING

1.  Always disconnect the appliance, let it completely cool and clean it before storing.

2.  If you do not use the device for a long period, put back the unit and the instruction 

manual to the original carton and store in a dry and ventilated place

3.  Do not place any heavy items on top of carton during storing as this may damage the 

appliance.

Summary of Contents for MHPH05-10E

Page 1: ...or any signs of damage If the product is damaged DO NOT USE and contact your supplier immediately for refund or replacement This product is only suitable for well insulated spaces or occasional use BE...

Page 2: ...competent able bodied adult Remove the packing and make sure that the appliance is intact If there is any doubt concerning the integrity of the unit do not use the appliance and contact our recommende...

Page 3: ...t be incorporated in the fixed wiring in accordance with the wiring rules For correct installation on the wall thanks to refer to Installation on wall part Fixed heaters are to be installed so that sw...

Page 4: ...ting carefully remove the already constructed hanging bracket from the rear of the heater by turning the two plastic securing grips located at the top of the bracket It is good practice to remove the...

Page 5: ...o electrical wiring gas pipes water pipes etc in the area to be drilled To fix the feet pls see the picture as below If not use for wall mounted pls assembly the feet as above picture CONTROL PANEL AN...

Page 6: ...y simply pressing the once and once again to revert back to set temperature Anti frost mode Press the button until the screen displays In this mode you cannot set the countdown timer or adjust the tem...

Page 7: ...r will stop working The screen will display Press to set the unit back to normal operation Figure 2 P2 Saturday Sunday preset program 00 00am 01 00am comfort mode 01 00am 08 00am ECO mode 08 00am 11 0...

Page 8: ...ing label Select your country code enter your mobile number and select Get to receive a message containing your verification code Enter your verification code and select Login When the first using to...

Page 9: ...u set P3 manually on the unit and you choose P3 in the APP the unit will operate to the settings you have set You can also choose to set to your own requirements by selecting the Smart Timer within th...

Page 10: ...on off background color changing If on the background color will change according to the temperature Room temperature calibration Use this function to set the Room Temperature Calibration to the corre...

Page 11: ...Pmax c elmax elmin elsb 1 0 1 0 No No 0 00061 no no no no Unit Nominal heat output kW kW kW kW kW With black bulb sensor no no no no no no yes yes yes no no no Contact details Hygiene Supplies Direct...

Page 12: ...u have any problems with this product please call our Help Desk on 0800 091 3171 or email sales hygienesuppliesdirect com Model identifier s MHPH05 20E P Manual heat charge control with integrated the...

Page 13: ...YESSS Electrical YESSS House Normanton WF6 1TN declares that the Mylek Heaters are exclusively manufactured and imported for Hygiene Supplies Direct Ltd...