background image

Figure 2

6

How to Wire This Ceiling Fan

WARNING

To avoid possible 

re or shock, be sure electricity is 

turned off at the main fuse box before wiring. 

(Figure 1)

Figure 1

MAIN FUSE BOX

Figure 3

Ceiling fans must be installed by a licensed electrician.  

WARNING

Check  to  see  that  all  connections  are  tight,  including 

earth, and that no bare wire is visible at the wire 

 

connectors, except for the earth wire.  Do not operate 

fan until the blades are in place.  Noise and motor damage 

 

 could result.

1.

 Securely attach the 9-pin connector from the hanger 

bracket to the wire harness socket of hanger ball. 

(Figure 2)

Installing Wall Control (Rotary) Switch

1.

 With electrical power still disconnected, install fan 

switch control wiring to desired location on wall.

2.

 Ensure wiring connections are as shown in Fig 2. The 

Active (Red) supply wire must be connected 

to terminal "C" on the rotary switch. Return switched wire 

to ceiling fan to be conected from terminal ˝1˝ on the rotary

switch to ˝L˝ terminal on the connector block.

3. 

Fit the wall control (rotary) switch to a face plate (not 

supplied) and attach to wall.

INSTALLATION NOTE:The “O” and the small corner 

cut-out on the front of the switch mechanism must be at 

the top and top left respectively (See Figure 3).

IMPORTANT: 

Fan installation must be completed, 

including the installation of the fan blades, before testing 

of the controls.

4.

 Restore electrical power to the ceiling fan by turning 

the electricity on at the main fuse box.

5.

 Check the operation of the fan by rotating the control 

through the four positions marked 0 - III 

(“0” position is OFF) (Figure 4).

6.

 All fans are shipped from the factory with the reverse

switch positioned to circulate air downward. 

If airflow is desired in opposite direction, turn your fan 

OFF and wait for the blades to stop turning, 

then slide the reversing switch to the opposite position, 

and turn fan on again.  

Figure 4

= OFF = FAST = MED

= SLOW

INSTALLATION NOTE: If light fixture is NOT required, 

terminate the black (Neutral) and red (Active) light wire.

Summary of Contents for FP6722AU

Page 1: ...OWNER S MANUAL READ AND SAVE THESE INSTRUCTIONS Model No FP6722 AU The Modn 4 Ceiling Fan Net Weight 8 87 kg 19 54 lbs ...

Page 2: ...urely mounted and capable of reliably supporting at least 27kg See page 4 of owner s manual for support requirements 4 The fan must be mounted with the fan blades at least 2 1 meter from the floor to prevent accidental contact with the fan blades 5 Follow the recommended instructions for the proper method of wiring this ceiling fan 6 This fan is not suitable for use with solid state controllers WA...

Page 3: ... be interrupted Wiring and connectors must be of type required by local regulations The minimum wire would be a 3 conductor 2 wire with ground Tools Needed for Assembly Materials NOTE If you are uncertain of part description refer to exploded view illustration Figure 1 page 10 3 1 Check to see that you have received the following parts Fan Motor Assembly Hanger Bracket End Plate Assembly Blade Set...

Page 4: ...possible electrical shock WARNING This fan must be installed by a licensed electrician Electrical and Structural Requirements s n a F g n i l i e C f o e s U t n e i c i f f E y g r e n E Ceiling fan performance and energy savings rely heavily on the proper installation and use of the ceiling fan Here are a few tips to ensure efficient product performance Turn Off When Not in the Room Ceiling fans...

Page 5: ...er batten or other structural support using appropriate fasteners Figure 3 WARNING Failure to seat tab in groove could cause damage to electrical wires and possible shock or fire hazard WARNING To avoid possible shock do not pinch wires between the hanger ball assembly and the hanger bracket 2 Carefully lift the fan and seat the downrod hanger ball assembly on the hanger bracket that was just attac...

Page 6: ...o ceiling fan to be conected from terminal 1 on the rotary switch to L terminal on the connector block 3 Fit the wall control rotary switch to a face plate not supplied and attach to wall INSTALLATION NOTE The O and the small corner cut out on the front of the switch mechanism must be at the top and top left respectively See Figure 3 IMPORTANT Fan installation must be completed including the insta...

Page 7: ...des assembled may result in damage to the fan blades WARNING To reduce the risk of personal injury do not bend the blades when installing balancing or cleaning the fan Do not insert foreign objects in between the rotating blades Blade Motor Assembly Figure 1 Ceiling Canopy Canopy Screw Cover NOTE Periodically check blade holder hardware and resecure if necessary 1 Secure the blades to the flywheel...

Page 8: ...sibility of electrical shock Blade Cleaning Periodic light dusting of the blades is recommended Avoid using water cleansers or harsh rags which can warp and ruin the blades 1 If you want to install the end plate assembly and not the light kit Assemble the end plate assembly to the motor assembly by twisting in a clockwise direction Figure 1 NOTE If you are installing the fan along with the Linea 4...

Page 9: ...illips Screwdriver 10 cm Blade Mounting Hardware Bag Containing 3 16 24 Screws with lock washers 13 8 32 Pan Head Screws 2 Hex Washer Phillips Head Tapping Screws Ø4 8 External Tooth Washer 2 Spring Washer 2 Flat Washers 2 Hanger Bracke Mounting Hardware Bag Containing Before discarding packaging materials be certain all parts have been removed Parts List Model FP6722 AU How To Order Parts When or...

Page 10: ...odn 4 Model FP6722 AU Exploded View NOTE The illustration shown is not to scale or its actual configuration may vary Product parts are subject to change without notice Figure 1 7 10 1 2 5 6 2a 2b 2c 2d 2e 3 4 ...

Page 11: ...e to the motor assembly are tight 3 Check to make sure the screws which attach the fan blade to the motor assembly are tight CAUTION Make sure main power is turned off 4 Tighten set screw securely 1 Blades not attached to fan 2 Loose screws in motor housing 3 Screws securing fan blade to motor assembly are loose 3 Screws securing fan blade to motor assembly are loose 4 Lower housing support set sc...

Page 12: ...ear cover to LED plate using the previously removed screws 8 Place glass into position and secure with finial by twisting in a clockwise direction Do not over tighten LED clear cover LED plate Glass Finial Motor assembly LED plate LED plate 6 Push end of light wire into either connector on the LED plate Repeat with other wire to other connector NOTE Ceiling fan light kits are only meant to be used...

Page 13: ...2015 01 V 01 ...

Reviews: