MYERS SR1830 Installation And Service Manual Download Page 3

25581A043  05/07/14

3

on, the switch is defective and must be replaced. 

Proceed to step 4. Then, with a new switch, repeat 

step 3. If pump turns on, the problem is solved.

 4. To replace switch, remove screw from tether 

clamp. In assembling new switch, position cable 

tie so the tether length is 2-7/8 – 3". Tighten cable 

tie and cut off excess length. Mount tie to the 

pump with a #10-24UNC x 1/2" long SST screw.

BASIN AND COVER REPAIR PARTS

25533D100 Basin 18 x 30 Regular Top for 

Solid Covers or Split Covers

25536C100 Cover, Solid, Domed Plastic,

(4) Hole, 2" or 3" Vent

25536C010 Cover, Split, 2" Vent
25536C011 Cover, Split, 3" Vent
25960D000 IAPMO Basin, 18 x 30 Regular Top 

for Solid Covers (16) Hole

25961C000 IAPMO Cover, Solid, Steel

(16) Hole, 2" Vent

25961C001 IAPMO Cover, Solid, Steel

(16) Hole, 3" Vent

25961C401 IAPMO Cover, Solid, Steel,

(16) Hole, 2" or 3" Vent

TYPICAL SEWAGE SYSTEM INSTALLATION

Summary of Contents for SR1830

Page 1: ...lease make sure you provide this manual to the owner of the equip ment or to the responsible party who maintains the system MODELS SR1830 and CMV1830 SUBMERSIBLE SEWAGE PUMPS INSTALLATION AND SERVICE MANUAL Part 25581A043 2014 Pentair Ltd 05 07 14 ...

Page 2: ...vestigated for use in swimming pools Never touch the sewage pump switch or discharge pipe when the pump is connected to electrical power Check the electrical circuit to make sure it meets the voltage and amperage requirement listed on the motor nameplate Your electrical service outlet should meet the National Electric Code and or local codes Your pump should have a separate branch circuit properly...

Page 3: ...ength Mount tie to the pump with a 10 24UNC x 1 2 long SST screw BASIN AND COVER REPAIR PARTS 25533D100 Basin 18 x 30 Regular Top for Solid Covers or Split Covers 25536C100 Cover Solid Domed Plastic 4 Hole 2 or 3 Vent 25536C010 Cover Split 2 Vent 25536C011 Cover Split 3 Vent 25960D000 IAPMO Basin 18 x 30 Regular Top for Solid Covers 16 Hole 25961C000 IAPMO Cover Solid Steel 16 Hole 2 Vent 25961C00...

Page 4: ...e protected by three leg ambient compensated extra quick trip overload relays of the recommended size or the warranty is void Your only remedy and MYERS s only duty is that MYERS repair or replace defective products at MYERS s choice You must pay all labor and shipping charges associated with this warranty and must request warranty service through the installing dealer as soon as a problem is disc...

Reviews: