MYERS SR1830 Installation And Service Manual Download Page 2

25581A043  05/07/14

2

MODELS SR1830 AND CMV1830

Your SR1830 or CMV1830 is designed to operate 

automatically or manually and for simple and quick 

installation. Its preset fluid level control allows for 

efficient operation when installed in a standard

18" x 30" sewage basin.

Before installing

 your pump, check carefully for 

shipping damage. Any claim for shipping damage 

must be made with your supplier at the point of 

purchase. 

The manufacturer cannot make shipping 

damage adjustments.

CALIFORNIA PROPOSITION 65 WARNING:

 This product and related 

accessories contain chemicals known to the 

State of California to cause cancer, birth 

defects or other reproductive harm.

INSTALLATION

This is a sewage handling pump and must be vented 

in accordance with local plumbing codes. This 

pump is not to be installed in locations classified as 

hazardous in accordance with National Electric Code, 

ANSI/NFPA 70.

The motor in your new submersible sewage pump is 

oil-filled for efficient operation. 

DO NOT loosen the 

three motor housing screws.

Place sewage pump on the bottom of the basin and 

position it to allow float to rise in center of basin. 

Check that nothing interferes with the float switch.

Slip cover over discharge pipe and power cord. 

Bolt cover securely to basin (be sure to use a cover 

gasket). Install discharge compression fitting and cord 

seal grommet.

CHECK VALVE

A properly designed full-flow check valve MUST 

be used on every installation. A series CV-200P is 

provided. It eliminates back-flow, reduces vibration 

and acts as a pipe union for easy servicing. Install on 

discharge pipe (make certain that arrow on valve body 

points in flow direction). Connect outlet of check valve 

to the plumbing line leading to the sanitary sewer 

system.

ELECTRICAL INFORMATION

WARNING: Risk of electric shock. This pump 

is supplied with a grounding conductor and 

grounding-type attachment plug. To reduce 

the risk of electric shock, be certain that it is 

connected only to a properly grounded, grounding-

type receptacle. Read instructions before installing 

pump. This pump has not been investigated for 

use in swimming pools.

Never touch the sewage pump, switch or 

discharge pipe when the pump is connected to 

electrical power.

Check the electrical circuit to make sure it meets the 

voltage and amperage requirement listed on the motor 

nameplate.

Your electrical service outlet should meet the National 

Electric Code and/or local codes. Your pump should 

have a separate branch circuit, properly fused and 

grounded. The outlet should be 4' above the floor and 

close enough to your pump that the original cord can 

reach it. 

Never use an extension cord.

Plug the switch power cord into a properly grounded 

outlet. Plug the pump power cord into the back of 

the switch cord plug. Tape the power cords to the 

discharge pipe every 12 inches to make sure any 

movement will not damage the insulation.

To test the system, add water to the sewage basin 

until the float switch operates normally.

Your pump has thermal overload protection. If the 

impeller becomes locked because of a foreign object, 

the motor will overheat and the thermal overload 

switch will cut off the electricity. Unplug pump and 

remove the foreign object immediately. See that the 

impeller turns freely.

SWITCH ADJUSTMENT AND 

REPLACEMENT INSTRUCTIONS

CAUTION: Always disconnect the pump and 

switch from the electrical power source before 

doing any maintenance! This pump is equipped 

with a float switch and does not control both 

sides of the electrical circuit. To reduce the risk 

of electric shock it is essential that it be wired in 

series with the hot side of the electrical circuit. 

Make sure your outlets are wired according to your 

local electrical code.

 1. Inspect the pump to be certain that there are no 

rocks, lint, etc. clogging the openings where water 

enters the pump housing. Remove any debris. 

Check to see that the impeller turns freely.

 2. Plug the pump power cord into a properly 

grounded, 3 hole outlet. If the pump works 

(impeller turns and air is blowing out of discharge 

opening), proceed to step 3. 

If the pump does not 

work, it must be replaced.

 3. If the pump works, (1) unplug pump and (2) replug 

into back of switch plug and (3) plug the assembly 

into the electrical outlet. Raise switch by hand to 

activate pump. If pump turns on, pump and switch 

are OK-no need to replace. If pump does not turn 

Summary of Contents for SR1830

Page 1: ...lease make sure you provide this manual to the owner of the equip ment or to the responsible party who maintains the system MODELS SR1830 and CMV1830 SUBMERSIBLE SEWAGE PUMPS INSTALLATION AND SERVICE MANUAL Part 25581A043 2014 Pentair Ltd 05 07 14 ...

Page 2: ...vestigated for use in swimming pools Never touch the sewage pump switch or discharge pipe when the pump is connected to electrical power Check the electrical circuit to make sure it meets the voltage and amperage requirement listed on the motor nameplate Your electrical service outlet should meet the National Electric Code and or local codes Your pump should have a separate branch circuit properly...

Page 3: ...ength Mount tie to the pump with a 10 24UNC x 1 2 long SST screw BASIN AND COVER REPAIR PARTS 25533D100 Basin 18 x 30 Regular Top for Solid Covers or Split Covers 25536C100 Cover Solid Domed Plastic 4 Hole 2 or 3 Vent 25536C010 Cover Split 2 Vent 25536C011 Cover Split 3 Vent 25960D000 IAPMO Basin 18 x 30 Regular Top for Solid Covers 16 Hole 25961C000 IAPMO Cover Solid Steel 16 Hole 2 Vent 25961C00...

Page 4: ...e protected by three leg ambient compensated extra quick trip overload relays of the recommended size or the warranty is void Your only remedy and MYERS s only duty is that MYERS repair or replace defective products at MYERS s choice You must pay all labor and shipping charges associated with this warranty and must request warranty service through the installing dealer as soon as a problem is disc...

Reviews: