interval and suitable energy of parameter value.

Ⅴ.

Safety Notice

4.1. Safety of E-light

The equipment takes maximum consideration of the safety of both operator and operatee in

the designing, the following are some safe measures of it:

Circuit self-checking after machine starting;

Using filter/light guide crystal, strong pulse light comes out only from the front side of the
handpiece.

Designed with independent safety circuit, electricity could be shut down automatically when
the IPL power is to high;

Emergency stop switch, shut down the power in emergency;

Key switch to avoid starting the machine by any people;

Use high quality engineering plastic frame, preventing electricity creepage.

Alarm

All strong pulsed light device may cause hurt by improper handling. Operators should keep

vigilant and take necessary protection measures according to the manual.

Operatee: Carry out the treatment in the professional treatment room; take effective eye

protecting measure;

Operator: wearing protective glasses;
Treatment room

marked the treatment room clearly with in operating of IPL.

To ensure to the safe use of the equipment, please read the following instructions carefully.

No one except technician authorized by the manufacture could dismantle or repair the
equipment, especially for the power source, handpiece; high voltage electricity inside;

Voltage rating: 110-120V;

Maintaining the equipment after disconnecting the power cord;

Keep the handpiece clean all the time; do not let the gel leaking into the handpiece;

In case leaking of the handpiece, do not start the equipment; already started, turning off
immediately;

No emitting light to one area repeatedly, otherwise may cause inflaming or burns, and may

Summary of Contents for HR-T350

Page 1: ...Page 1 in 12 pages Please read the instructions before use Brief Introduction E light applies three core technology IPL RF and epidermis cooling It combines the USER MANUAL...

Page 2: ...hermolysis effect Since light energy is far below conventional IPL the pigment tissue and vascular pathological tissue of the corium and epidermis would absorb more energy without injuring the epiderm...

Page 3: ...ense pulsed light source xenon lamp B Reflector and filter C Sapphire wave guide 2 Technique Specification Light Energy 1 50J cm2 RF energy 1 25J SR Spectra 530 1200nm Cooling water air semi conductor...

Page 4: ...ing the gel evenly 2 3mm on the skin Effect light guide cooling anaesthetisin Attention no coating on eyes eyebrows lips 2 6 Eye protection Operator wear the safety goggles Patient close the eyes wear...

Page 5: ...ction before for similar operation fill the Client File concretely Adjust the parameters on the basis of full acquaintance of the condition of operatee Inform the operatee the possible reation in oper...

Page 6: ...3 4 2 Double confirm there is no leaking of water circulation fold the protective cover by turning it right 3 5 Debugging 3 5 1 Make sure water and electric circuit is correct connected then turn on t...

Page 7: ...e wanted treatment program by clicking 3 6 2 Operation Interface Operation Interface Treatment mode 3 groups of different parameters setting Pulse1 working time of the first pulse Pluses sub pulse wid...

Page 8: ...amp is on but could not make shots start pause click start zimmer the handle and the capacitor charge automatically system will enter the treatment status when charge is ready Click stop escape from t...

Page 9: ...Blackhead and oil comeout in 2 3 days and disappear in 7 days Parameter control Long pulse width short interval high energy 3 8 7 Winkle pouch black circle Light pain Parameter control Short pulse wi...

Page 10: ...t by improper handling Operators should keep vigilant and take necessary protection measures according to the manual Operatee Carry out the treatment in the professional treatment room take effective...

Page 11: ...wer therefore do not dismantle the backboard without under supervising by our technicians Do not move the equipment by pulling the handpiece Do not use the equipment in inflammable and explosive envir...

Page 12: ...tion and user manual The warranty does not extend to any equipment that a Malfunctions caused by abused operation b Malfunctions caused by modification or repair by anyone except EASYLASER or not auth...

Reviews: