6. Descriptions on maintenance 

6.1. Faults   

1.  When 220V AC is connected, the power indicator light is 

not on.   

2.  The  power  supply  is  normal,  but  the  Uplink  and 

Downlink power indicator lights are not on even with the 

signals received.   

6.2. Troubleshooting   

1.  When the 220V AC is powered, the power indicator light 

is  not  on.  Firstly,  check  if  the  AC  socket  is  in  good 

conditions  and  then  check  if  the  220V  power  is  in  the 

normal  state  with  a  multimeter  at  the  voltage  of  AC 

750V. 

2.  If  the  power  supply  is  confirmed  to  be  normal  and  the 

signal  is  applicable,  the  Uplink  and  Downlink  power 

indicator lights are not on, check if cables are correctly 

connected,  and  if  the  position  and  orientation  of  the 

antenna are appropriate.   

3.  The  above-mentioned  check  methods  are  mainly 

applied  for  jobsite  maintenance.  In  general,  only  a 

multimeter  is  used  instead  of  large  size  instruments. 

Please  contact  the manufacturer  if  the malfunction  still 

cannot 

be 

removed 

after 

implementing 

the 

above-mentioned  methods  of  1  and  2.  HP8713D 

network analyzer may be used for testing in the process 

of maintaining in the labs or production plants. Different 

malfunctions shall adopt different methods.   

 

Service is forever 

This  User  Manual  concerns  the  signal  amplifier  product 

series of our company. Some omissions are inevitable due 

to  insufficient  preparing  time.  For  any  question,  please 

contact us for correction. We are ready for reply and serve 

you wholeheartedly. 
We  sincerely  hope  that  this  User’s  Manual  will  bring  you 
convenience,  the  changes  of  the  standards,  technical 

requirements or varieties of product dimensions involved in 

this User Manual may result in revision without notification 

to you as technology develops and time goes by. 

 

 

   

 

 
 
 
 

 

   

 

 

 

 

 

Summary of Contents for Nikrans NS-1000 3G

Page 1: ...0 3G model 3G connection 2100MHz Coverage 1000 m2 Contents 1 Purposes 2 Technical features 3 Technical specifications 4 System configuration 5 Operation instructions 5 1 Descriptions of the overall di...

Page 2: ...ue to the shield effect to electro magnetic waves caused by buildings the mobile communication signals cannot be received in tunnels subways underground stores entertainment complex parking fields hot...

Page 3: ...osed of a host signal amplifier reverse antenna and in door covering system Reverse antenna aims at the reverse base station that requires for expanding the coverage the BTS Port of the host signal am...

Page 4: ...ntenna through radio frequency cable In general the reverse antenna is mounted at a higher position Yagi antenna and panel antenna may be used The main lobe of the antenna radiation is oriented toward...

Page 5: ...o two hours around for further test 6 Recheck the whole system and clean up the working site 7 Record the work and fill in the Engineering Records Form in details and make the archives as well Notice...

Page 6: ...antenna are appropriate 3 The above mentioned check methods are mainly applied for jobsite maintenance In general only a multimeter is used instead of large size instruments Please contact the manufa...

Page 7: ...rance E mail contact myamplifiers com Skype gsm_amplifier www myamplifiers com Contact Us Customer Service contact information E mail contact myamplifiers com MSN contact myamplifiers com Skype gsm_am...

Reviews: