Step 4: Installing Blower
•Note: If you are using a mantel with your
heater, see (Figure: 4). If your heater is
Built-In Installation, see (Figures: 4 & 5)
for where Power Cord plugs into the Outlet
Receptacle.
•In top of heater cabinet, locate four mount-
ing holes on Back Wall. Align the four holes
with those on blower bracket assembly.
Secure blower bracket assembly to Back
Wall with 4 screws and place Heat Sensor
on Compartment Floor to the Right of
Blower (Figure: 4).
•Route Cord Set through hole in lower left
Side Panel. Pull Cord Set through lower
opening above where Valve Cover Shield
was removed. (Figure: 4.)
•Insert the 3 wires of Cord Set into one of
the round holes of Valve Cover Shield
Backing and through Rectangular Hole in
front of Valve Cover Shield (Figure: 4).
•Reconnect Green, White and Black wires to
where they were previously connected.
•Install switch plate on Valve Cover Shield
with 2 screws provided (Figure: 6)
Installer is responsible to check local codes
and read all instructions prior to installation.
Layout designed in U.S.A. © 2022
NOTE: Diagrams and Illustrations NOT to Scale
Page 3 of 4
MyFireplaceBlower.com
My Fireplace Blower LLC
Burlington, Wisconsin
1-800-466-4045
Figure: 4
Figure: 5
Step 5: Reinstall Valve Cover Shield (Figures: 3 & 4).
•Route power cord out of cabinet by inserting it through
hole on lower Side Panel (Figure: 4).
•Note: If you are using a mantel with your heater, see
(Figure: 4), if your
Fireplace is Built-In see Below
.
For Built-In Installation
, reference (Figure: 5) for
location where the Power Cord plugs into the Outlet
Receptacle. *A licensed electrician must install the
Outlet Receptacle from the incoming electrical supply
to Valve Cover Shield in compliance to Local or
National Code (Figure: 5).
OFF
ON
For Built-In
Install snap bushings found in hardware kit into both holes
Make sure the wire harness is
firmly
connected to all
Cord Set
Blower
Assembly
Screw
Power
Cord
Valve
Cover
Shield
Valve Cover Shield Backing
Cord
Set
Switch Bracket
Rocker
Switch
Compartment
Floor
Hole to Channel Wires
in Compartment Floor
Power
Cord
Valve
Cover
Shield
Valve Cover
Shield Backing
Clamp Connector
(not included)
* Outlet
Receptacle