My Fireplace Blower GA3450TA Installation Instructions Download Page 3

Step 4: Installing Blower

•Note: If you are using a mantel with your 

 heater, see (Figure: 4). If your heater is 

 Built-In Installation, see (Figures: 4 & 5) 

 for where Power Cord plugs into the Outlet 

 Receptacle.

•In top of heater cabinet, locate four mount-

 ing holes on Back Wall. Align the four holes   

 with those on blower bracket assembly. 

 Secure blower bracket assembly to Back   

 Wall with 4 screws and place Heat Sensor  

 on Compartment Floor to the Right of

 Blower (Figure: 4).

•Route Cord Set through hole in lower left  

 Side Panel. Pull Cord Set through lower 

 opening above where Valve Cover Shield  

 was removed. (Figure: 4.)

•Insert the 3 wires of Cord Set into one of 

 the round holes of Valve Cover Shield 

 Backing and through Rectangular Hole in  

 front of Valve Cover Shield (Figure: 4).

•Reconnect Green, White and Black wires to  

 where they were previously connected.

•Install switch plate on Valve Cover Shield  

 with 2 screws provided (Figure: 6)

CLICK

Installer is responsible to check local codes 

and read all instructions prior to installation.

Layout designed in U.S.A. © 2022

NOTE: Diagrams and Illustrations NOT to Scale

Page 3 of 4

MyFireplaceBlower.com

:

My Fireplace Blower LLC

Burlington, Wisconsin

1-800-466-4045

Figure: 4

Figure: 5

Step 5: Reinstall Valve Cover Shield (Figures: 3 & 4).

•Route power cord out of cabinet by inserting it through 

 hole on lower Side Panel (Figure: 4).

•Note: If you are using a mantel with your heater, see 

 (Figure: 4), if your 

Fireplace is Built-In see Below

For Built-In Installation

, reference (Figure: 5) for 

 location where the Power Cord plugs into the Outlet 

 Receptacle.  *A licensed electrician must install the 

 Outlet Receptacle from the incoming electrical supply 

 to Valve Cover Shield in compliance to Local or 

 National Code (Figure: 5).

OFF

ON

For Built-In 

Install snap bushings found in hardware kit into both holes 

Make  sure  the  wire  harness  is 

firmly

  connected  to  all 

Cord Set

  Blower 

Assembly

 

Screw 

Power 

Cord 

Valve 

Cover 

Shield 

Valve Cover Shield Backing 

Cord 

 Set

Switch Bracket 

Rocker 

Switch

Compartment

        Floor 

Hole to Channel Wires 

in Compartment Floor

 

Power 

Cord 

Valve 

Cover 

Shield 

  Valve Cover 

Shield Backing 

Clamp Connector 

(not included) 

  * Outlet 

Receptacle 