Drywall dust or other fragments may be present in your fireplace’s vent space, clean this area before you install the
blower kit. Any bearing or motor damage resulting from this condition is not covered by the warranty policy.
Instructions for BLOT240 Blower Kit with Cord Set
This Blower Kit is tested and safe when installed in accordance with these installation instructions. It is your re-
sponsibility to read all instructions and consult the Owner’s Installation Manual for your particular model number
for Supplemental Information before starting installation. Blower operates on 120V/60Hz power.
High Quality Aftermarket Fireplace Blowers & Fans
1-800-466-4045
Check the contents of the carton.
Make sure nothing was damaged in shipment.
Do NOT install a damaged blower kit!
Blower Kit Parts
Step 1: Turn Off Fireplace and allow it to cool
down. Disconnect from 120V Power. Shut off
the Gas supply. Remove the louver which cov
-
ers the lower vent space below the firebox.
(Figure: 3A)
Lay cord set out in a straight line, with the
3-Prong Power Plug furthest away from the
fireplace.
NOTE: Diagrams and Illustrations NOT to Scale
Page 1 of 4
WARNING
RISK OF FIRE AND ELECTRICAL SHOCK!
TURN OFF THE GAS AND ELECTRICAL POWER BEFORE INSTALLING BLOWER!
When installed, make sure to contain any excess wire of the cord set;
Preventing it from making contact with moving or hot objects.
Description
Qty.
Fan
Thermodisc / Heat Sensor
Variable Speed Control
Cord Set with Hi-Temp Wire Leads
Velcro Strip
Foam Dampening Pad
Installation Instructions
(Downloadable)
1
1
1
1
1
1
2
Step 2:
Wear gloves when handling the Hi-Temp wire,
fiberglass particles are present. Disconnect the blue con
-
nector on white Hi-Temp wire from purple connector on
white wire coming from the Variable Speed Control.
2A)
Open the top louver.(If you can not access this loca
-
tion, go to Step 2: B)
Run the 2 Hi-Temp wires down the side. Place magnetic
thermodisc/heat sensor to the warmest spot on the right
side of the firebox, 1-3 inches down and 1-4 inches to
-
wards center. (Figure: 1)
In lower vent space, reach and gently pull Hi-Temp wire
ends towards center.
2B)
From the lower vent space, position the magnetic
thermodisc/heat sensor up the side of the firebox 2-4
inches and 2-5 inches toward center. (Figure: 1)
The thermodisc will activate the blower when it senses
120°F and will automatically turn the blower off after the
fireplace cools below 90°F. (You may have to change the
position of the thermodisc until you find a hot spot).