5. SITE REQUIREMENTS

The installation must be in accordance with Water 

Regulations Advisory Service (www.wras.co.uk).

Minimum running water pressure: 0.1 bar, but will 

operate better at a minimum of 0.5 bar.

Maximum running water pressure: 5 bar. Maximum 

static water pressure: 10 bar.

For your shower to perform well you should ensure 

that the pressure is as specified and a minimum flow 

of 5 litres per minute is available at both hot and cold 

inlets.

If the water supply is fed by a gravity system then 

the supply pressure should be verified to ensure the 

conditions of use are appropriate for the valve.

NOTE:  Water Regulations requires the handset to 

be ‘constrained by a fixed or sliding attachment so 

that it can only discharge water at a point not less 

than 25mm above the spill over level of the relevant 

bath, shower tray or other fixed appliance’. A double 

check valve, or similar, MUST be fitted in the supply 

pipe work to prevent back-flow.

The pressure at both the hot and cold water 

supplies to the mixer valve should be the same, 

and the installer should ensure that the flow is not 

affected by other taps elsewhere in the house. It is 

very important that for use in any mains pressure 

systems an expansion tank and a pressure reducing 

valve has been fitted to ensure the pressure does 

not exceed 5 Bar. 

This should be confirmed by the installation 

engineer or competent person  before installation. 

WATER TEMPERATURE REQUIREMENTS

Maximum hot water temperature = 80°C, 

Recommended maximum = 65°C.

Minimum hot water temperature = 55°C

Maximum cold water temperature = 20°C

TEMPERATURE ADJUSTMENT RANGE

The mixed water temperature can be adjusted from 

cold through to hot. There is a safety stop preset at a 

set temperature of about 38°C. Always test the water 

temperature prior to using the shower.

In the event of failure of cold water system, the mixer 

valve automatically reduces the flow of hot water to 

prevent scalding. It will only operate again once the 

flow of cold water has been resumed.

Summary of Contents for Atmos Zone

Page 1: ...Fitting Instructions IMPORTANT This Step by Step guide should be retained after installation Atmos Zone Thermostatic Concealed Concentric Mixer Valve with Fixed Head...

Page 2: ...resystemsuptoamaximumof5barrunning pressure Themixervalvemustnotbesubjectedto watertemperaturesabove80 C Thismixervalveis alsosuitableforthermalstorage unventedsystems andpumpedgravitysystems IMPORTAN...

Page 3: ...FilterWashers 2 PlainWashers 2 FlowController 1 AllenKey 1 PressureBalanceKit 1 ScrewPack 3screws 3plugs 1 FittingInstructions 1 TMVRegistrationCard 1 Allen Key Pressure Balance Kit Screw Pack Fittin...

Page 4: ...dent method of isolating the shower should maintenance or servicing be necessary these valves SHOULD NOT restrict the flow DO NOT operate the shower outside the recommended temperatures and pressures...

Page 5: ...MUSTbefittedinthesupply pipeworktopreventback flow Thepressureatboththehotandcoldwater suppliestothemixervalveshouldbethesame andtheinstallershouldensurethattheflowisnot affectedbyothertapselsewherein...

Page 6: ...uldpointupwards n Themixervalveisdesignedtoworkatthesame hotandcoldwaterpressures Ifthisisnotthecasea flowcontroller discwithsmallholes canbefittedto thehigherpressuresupplytothevalve Thisisbest doneb...

Page 7: ...ouldbe fixedtothewallbetween50mmand70mmbelow thefinishedsurfaceoftheshower 5 Thesupplypipeworkcanbeplumbedfromabove orbelowbutmustfinishatthesuitableconnections whichshouldbeat155mmcenters Connectthe...

Page 8: ...whentheshowerisoff 10 Thetrimplateisfittedbypushingitontothemixer valveuntilflushwiththetiles Fig6 NOTE Beforeassemblingthevalvecontrolsidentify allthepartsandcheckthatredmarkeingsonthe thermostaticca...

Page 9: ...erboard 3 Removefittingsandnutfromendofarmthrough wall re fitwasherandnut 4 Connectwallarmtothepipeworkinstalledfrom thevalve 5 Whenattachingthefixedshowerheadmakesure thesealingwasherisinplaceandscre...

Page 10: ...ets 3 Overridethetemperaturestopbuttonbypressing thebuttonandrotatetomaximumbeingcarefulto avoidscalding Measurethetemperature 4 Thevalveshouldthenbecheckedtoconfirmthe waterisolationperformscorrectly...

Page 11: ...evalveandcleanfilters 4 Showerheadblocked CleanShowerhead 5 Systemnotcapableofsupplyingmultipleoutlet atthesametime Reducesimultaneousdemand Checkstop servicevalvesarefullyopen Checkifenough waterpres...

Page 12: ...toyouthecustomer 2 Thisguaranteeispersonaltotheoriginalpurchaserofthe productandisnottransferable 3 Originalproofofpurchase s mustbeshownforanyclaim underthisguarantee 4 Thisguaranteedoesnotcoveranypr...

Page 13: ...gineersvisit Theengineerwillnot beabletorepairorreplaceoradviseonpartsor productsnotsuppliedbyMX 4 Intheeventofaservicecallabortedbyyouor whereacallhasbeenbookedunderourguarantee butfailureisnotrelate...

Page 14: ...NOTES...

Page 15: ...NOTES...

Page 16: ...sales mx group com www mx group com CUSTOMERCARE 08455052211 TRADE DESCRIPTIONS ACT Variations in terms of colour finish materials and all other aspects of appearance may occur on occasions either thr...

Reviews: